- 4 - 

 

VFR4000-OMH0003-D 

 

Design / Selection 

 
 

1. Confirm the specifications. 

Products represented in this catalog are designed only for use 

in compressed air systems (including vacuum). Do not operate 

at pressures, temperatures, etc., beyond the range of 

specifications, as this can cause damage or malfunction. (Refer 

to the specifications.) Please contact SMC when using a fluid 

other than compressed air (including vacuum). We do not 

guarantee against any damage if the product is used outside of 

the specification range. 

2. Actuator drive 

When an actuator, such as a cylinder, is to be driven using a 

valve, take appropriate measures (such as the installation of a 

cover or the restricting of access to the product) to prevent 

potential danger caused by actuator operation.

 

3. Intermediate stops 

For the 3-position closed center or double check valve types, it 

is difficult to make the piston stop at the required position 

accurately due to the compressibility of air. 

Furthermore, since valves and cylinders are not guaranteed for 

zero air leakage, it may not be possible to hold a stopped 

position for an extended period of time. Please contact SMC if it 

is necessary to hold a stopped position for an extended period 

of time. 

4. Effects of back pressure when using a manifold   

Use caution when valves are used on a manifold because 

actuators may malfunction due to back pressure. 

Especially when using a 3-position exhaust center valve or a 

single acting cylinder take appropriate measures to prevent 

malfunction by using it with an individual EXH spacer 

assembly(VVFS4000-R-04-1,2). 

5. Holding pressure (including vacuum) 

Since valves are subject to air leakage, they cannot be used for 

applications such as holding pressure (including vacuum) in a 

pressure vessel. 

6. Not suitable for use as an emergency shutoff valve, 

etc. 

The valves listed in this catalog are not designed for safety 

applications such as an emergency shutoff valve. If the valves 

are used in such applications, additional safety measures 

should be adopted. 

7. Release of residual pressure 

For maintenance and inspection purposes install a system for 

releasing residual pressure. Especially in the case of the 

3-position closed center valve or double check valve types, 

ensure that the residual pressure between the valve and the 

cylinder is released. 

8. Operation in a vacuum condition 

When a valve is used for switching a vacuum, take measures to 

install a suction filter or similar to prevent external dust or other 

foreign matter from entering inside the valve. In addition, at the 

time of vacuum adsorption, be sure to supply a constant supply 

of vacuum. Failure to do so may result in foreign matter sticking 

to the adsorption pad or air leakage, causing the workpiece to 

drop. 

 

9. Ventilation 

Provide ventilation when using a valve in a confined area, such 

as in a closed control panel. For example, install a ventilation 

opening, etc., in order to prevent pressure from increasing 

inside of the confined area and to release the heat generated 

by the valve. 

10. Extended periods of continuous energization

 

If a valve will be continuously energized for an extended period 

of time, the temperature of the valve will increase due to the 

heat generated by the coil. This will likely adversely affect the     

performance of the solenoid valve and any nearby peripheral 

equipment. Therefore, when it is continuously energized or the 

energized period per day is longer than the de-energized period 

use a DC specification valve. For applications such as 

mounting a valve on a control panel, incorporate measure to 

limit the heat radiation so that it is within the operating 

temperature range. For example, the temperature will be high 

when a 3 station manifold or larger is put next to other valves 

and continuously energized. 
If conflicting instructions are given in the “Specific Product 
Precautions” or on the “How to Order Valves” page, give them 

priority. 

11.Do not disassemble the product or make any 

modifications, including additional machining. 

Doing so may cause human injury and/or an accident. 

12.Resumption after a long period of holding time

 

When resuming operation after a long period of holding time, 

there are cases in which, regardless of whether the product is 

in an ON or OFF state, there is a delay in the initial response 

time due to adhesion. Conducting several cycles of running-in 

operation will solve this problem. Please consider implementing 

this before resumption.

   

 

 

1. Precautions for 2-position double solenoid valves

 

If a double solenoid valve is operated with momentary 

energization, it should be energized for at least 0.1 seconds. 

However, depending on the piping conditions, the cylinder may 

malfunction even when the double solenoid valve is energized 

for 0.1 seconds or longer. In this case, energize the double 

solenoid valve until the cylinder is exhausted completely.

   

2. Leakage voltage 

Take note that the leakage voltage will increase when a resistor 

is used in parallel with a switching element or when a C-R 

circuit (surge voltage suppressor) is used for protecting a 

switching device because of the leakage voltage passing 

through the C-R circuit. The suppressor residual leakage 

voltage should be as follows. 

DC coil

 

3% or less of the rated voltage 

AC coil

 

20% or less of the rated voltage 

 

 

 

VFR4000 Series 

5 Port Solenoid Valve / Precautions 1

 

 

 

Be sure to read before handling.

 

 

Warning 

Caution 

   

Содержание VFR4000 Series

Страница 1: ...Doc No VFR4000 OMH0003 D PRODUCT NAME 5 Port Solenoid Valve MODEL Series VFR4000 Series...

Страница 2: ...nstructions 2 3 Precautions on Design Selection 4 5 Mounting 5 Piping 5 6 Wiring 6 Lubrication 6 Air Supply 6 Operating Environment 7 Maintenance 7 Specific Product Precautions 8 to 11 Construction 12...

Страница 3: ...quipment failure when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectly Th...

Страница 4: ...ailure of the product 3 Prior to using SMC products please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products 2 Vacuum pads are excluded...

Страница 5: ...constant supply of vacuum Failure to do so may result in foreign matter sticking to the adsorption pad or air leakage causing the workpiece to drop 9 Ventilation Provide ventilation when using a valv...

Страница 6: ...valves and external pilot type valves are used on the same manifold Additionally when compressed air within the pressure range of the established specifications is supplied to the external pilot type...

Страница 7: ...ide the pilot valve causing malfunction or response delay So do not apply a large amount of oil When a large amount of oil needs to be applied use an external pilot type to put the supply air on the p...

Страница 8: ...irst confirm that measures are in place to prevent workpieces from dropping run away equipment etc Then cut off the supply pressure and electric power and exhaust all compressed air from the system us...

Страница 9: ...2 3 to 2 8 mm Type D Y 4 5 to 7 mm Applicable crimp terminal Type E T 1 25 3 1 25 3S 1 25Y 3N 1 25Y 3S Round shape or Y shape crimp terminal cannot be used for Type D DIN terminal block type VFR4 10...

Страница 10: ...exhaust port leaving open How to Exchange Solenoid Valves Pilot Valve Assemblies How to exchange solenoid valves Loosen set screw and take solenoid valve out vertically otherwise it may cause damage...

Страница 11: ...annot be used for intermediate stops of a cylinder because there is leakage from relief port on the regulator Type 01T with Terminal Block Remove junction cover of manifold exposing terminal block att...

Страница 12: ...and COM Note 3 Station numbers are started from D side although connector is mounted on D or U Side Type 01F D sub Connector MIL standard type D connector Terminal 25 pins has wide exchangeability an...

Страница 13: ...12 VFR4000 OMH0003 D VFR4000 Series Construction Be sure to read this before handling...

Страница 14: ...13 VFR4000 OMH0003 D VFR4000 Series Construction Be sure to read this before handling...

Страница 15: ...ly shifted 1 2 3 4 6 Coil splashed by water Low pilot pressure Intrusion of foreign matter Poor contact at contactor wire or connection part Low line voltage Higher voltage or wrong coil used Burnt co...

Страница 16: ...n this case stop usig the valve immediately 15 Supply specified pressure to X port Single solenoid 3 position 0 2 to 0 9 MPa Double solenoid 0 1 to 0 9 MPa When a large quantity of drain is given and...

Страница 17: ...1 Sotokanda Chiyoda ku Tokyo 101 0021 JAPAN Tel 81 3 5207 8249 Fax 81 3 5298 5362 URL https www smcworld com Note Specifications are subject to change without prior notice and any obligation on the p...