background image

 

 

 

VFR4000-OMH0003-D 

 

 

Contents

 

 

Safety Instructions    ----------------------------------------------------------------------------    2, 3 

 

Precautions on Design / Selection ----------------------------------------------------------    4, 5 

 

Mounting    ----------------------------------------------------------------------------------------    5 

 

Piping    --------------------------------------------------------------------------------------------    5,6 

 

Wiring    --------------------------------------------------------------------------------------------    6 

 

Lubrication    --------------------------------------------------------------------------------------    6 

 

Air Supply    ---------------------------------------------------------------------------------------    6 

 

Operating Environment    ----------------------------------------------------------------------    7 

 

Maintenance    ------------------------------------------------------------------------------------    7 

 

Specific Product Precautions    ---------------------------------------------------------------    8 to 11 

 

Construction    ------------------------------------------------------------------------------------    12,13 

 

Trouble shooting    -------------------------------------------------------------------------------    14 

 

 

 

 

 

 

 

 

 

   

Remedy    ------------------------------------------------------------------------------------------    15 

 

 

 

 

 

 

 

 

 

 

 

 

- 1 -

 

Содержание VFR4000 Series

Страница 1: ...Doc No VFR4000 OMH0003 D PRODUCT NAME 5 Port Solenoid Valve MODEL Series VFR4000 Series...

Страница 2: ...nstructions 2 3 Precautions on Design Selection 4 5 Mounting 5 Piping 5 6 Wiring 6 Lubrication 6 Air Supply 6 Operating Environment 7 Maintenance 7 Specific Product Precautions 8 to 11 Construction 12...

Страница 3: ...quipment failure when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectly Th...

Страница 4: ...ailure of the product 3 Prior to using SMC products please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products 2 Vacuum pads are excluded...

Страница 5: ...constant supply of vacuum Failure to do so may result in foreign matter sticking to the adsorption pad or air leakage causing the workpiece to drop 9 Ventilation Provide ventilation when using a valv...

Страница 6: ...valves and external pilot type valves are used on the same manifold Additionally when compressed air within the pressure range of the established specifications is supplied to the external pilot type...

Страница 7: ...ide the pilot valve causing malfunction or response delay So do not apply a large amount of oil When a large amount of oil needs to be applied use an external pilot type to put the supply air on the p...

Страница 8: ...irst confirm that measures are in place to prevent workpieces from dropping run away equipment etc Then cut off the supply pressure and electric power and exhaust all compressed air from the system us...

Страница 9: ...2 3 to 2 8 mm Type D Y 4 5 to 7 mm Applicable crimp terminal Type E T 1 25 3 1 25 3S 1 25Y 3N 1 25Y 3S Round shape or Y shape crimp terminal cannot be used for Type D DIN terminal block type VFR4 10...

Страница 10: ...exhaust port leaving open How to Exchange Solenoid Valves Pilot Valve Assemblies How to exchange solenoid valves Loosen set screw and take solenoid valve out vertically otherwise it may cause damage...

Страница 11: ...annot be used for intermediate stops of a cylinder because there is leakage from relief port on the regulator Type 01T with Terminal Block Remove junction cover of manifold exposing terminal block att...

Страница 12: ...and COM Note 3 Station numbers are started from D side although connector is mounted on D or U Side Type 01F D sub Connector MIL standard type D connector Terminal 25 pins has wide exchangeability an...

Страница 13: ...12 VFR4000 OMH0003 D VFR4000 Series Construction Be sure to read this before handling...

Страница 14: ...13 VFR4000 OMH0003 D VFR4000 Series Construction Be sure to read this before handling...

Страница 15: ...ly shifted 1 2 3 4 6 Coil splashed by water Low pilot pressure Intrusion of foreign matter Poor contact at contactor wire or connection part Low line voltage Higher voltage or wrong coil used Burnt co...

Страница 16: ...n this case stop usig the valve immediately 15 Supply specified pressure to X port Single solenoid 3 position 0 2 to 0 9 MPa Double solenoid 0 1 to 0 9 MPa When a large quantity of drain is given and...

Страница 17: ...1 Sotokanda Chiyoda ku Tokyo 101 0021 JAPAN Tel 81 3 5207 8249 Fax 81 3 5298 5362 URL https www smcworld com Note Specifications are subject to change without prior notice and any obligation on the p...

Отзывы: