Testing the Installation
1. Power up or reset the hub and check the LEDs (refer to
“Connecting Power” in Chapter 2).
2. If the Power LED is not lit and there is no activity on the
entire unit:
• Check the connections between the hub, the power
cord, and the wall outlet.
• Check the connections to the punch-down block and
patch panel (if the hub is installed in a rack).
If the Power LED still does not light, contact SMC Tech
Support.
3. If the NMM LED blinks yellow, the power-on diagnostics
have failed. Contact SMC Tech Support.
4. If the Port Status LEDs are not responding:
• Check the connections between each network device
and the hub port, including wiring.
• Check that the devices are powered on and functioning
properly.
5. If the BNC Port Status LED is yellow, be sure the cable
attached to this port is properly terminated.
Note:
If the BNC port is not used, it does not need to be
terminated.
41
T
ROUBLESHOOTING