Table 1. Return unit flow switch output specification
Type
Symbol
OUT1
OUT2
Temp.
sensor
Flow rate
Flow rate
Temp.
Remote sensor
1
Analogue 1 to 5 V
-
-
None
2
Analogue 4 to 20 mA
-
-
1T
Analogue 1 to 5 V
-
Analogue 1 to 5 V
With temp.
sensor
2T
1
Analogue 4 to 20 mA
-
Analogue 4 to 20 mA
Integrated display
type
A
NPN
NPN
-
None
B
PNP
PNP
-
C
NPN
Analogue 1 to 5 V
-
D
NPN
Analogue 4 to 20 mA
-
E
PNP
Analogue 1 to 5 V
-
F
PNP
Analogue 4 to 20 mA
-
G
1
NPN
External input
2
-
H
1
PNP
External input
2
-
AT
NPN
(NPN)
3
NPN
With temp.
sensor
BT
PNP
(PNP)
3
PNP
CT
NPN
(Analogue 1 to 5 V)
3
Analogue 1 to 5 V
DT
NPN
(Analogue 4 to 20 mA)
3
Analogue 4 to 20 mA
ET
PNP
(Analogue 1 to 5 V)
3
Analogue 1 to 5 V
FT
PNP
(Analogue 4 to 20 mA)
3
Analogue 4 to 20 mA
: When the remote sensor and remove type monitor are combined (PF3W3 series), select the flow rate with analogue output 1 to 5 V
(When the output signal is “1”, select “1T”).
Type
Symbol
OUT1
OUT2
Temp.
sensor
Flow rate/temp.
5
Flow rate/temp.
5
Integrated display
type
(IO-Link compliant
4
)
L
IO-Link/switch output (N/P)
-
None
L2
1
IO-Link/switch output (N/P)
Switch output (N/P)
LT
IO-Link/switch output (N/P)
-
With temp.
sensor
L2T
1
IO-Link/switch output (N/P)
Switch output (N/P)
1: Made to Order.
2: External input: resets the accumulated value, peak value and bottom value.
3: When the temperature sensor is equipped, either of temperature output or flow rate output can be selected only for OUT2.
The default setting is temperature output.
4: IO-Link is only available in the display integrated type.
5: When
“without temperature sensor (symbol: “L”, “L2”) is selected, temperature output and setting cannot be performed.
Содержание PF3W504
Страница 12: ...11 No PF OMW0004 A Model Indication and How to Order Integrated type Basic type...
Страница 13: ...12 No PF OMW0004 A Integrated type Straight type...
Страница 14: ...13 No PF OMW0004 A Remote type Supply type...
Страница 15: ...14 No PF OMW0004 A Remote type Return type...
Страница 51: ...50 No PF OMW0004 A Characteristics graph Measurable range of ethylene glycol aqueous solution reference value...
Страница 55: ...54 No PF OMW0004 A Flow range 2 to 16 L min symbol 20 reference value Nil S P W...
Страница 56: ...55 No PF OMW0004 A Flow range 5 to 40 L min symbol 40 reference value Nil S P W...
Страница 58: ...57 No PF OMW0004 A Flow range 2 to 16 L min symbol 20 reference value Nil S P W...
Страница 59: ...58 No PF OMW0004 A Flow range 5 to 40 L min symbol 40 reference value Nil S P W...