Specifi cations
Model
PFG300
series
Applicable SMC
fl ow switch
Model
PFMC7501
PFMC7102
PFMC7202
Rated fl ow range
∗
1
5 to 500
l/
min
10 to 1000
l/
min
20 to 2000
l/
min
Flow
Set point
range
Instantaneous fl ow
−25 to 525
l/
min
−50 to 1050
l/
min
−100 to 2100
l/
min
Accumulated fl ow
0 to 999,999,999,990 L
Smallest settable
increment
Instantaneous fl ow
1
l/
min
Accumulated fl ow
10 L
Accumulated volume per pulse
(Pulse width = 50 ms)
1 L/pulse
10 L/pulse
Accumulated value hold function
∗
3
Intervals of 2 or 5 minutes can be selected. The stored accumulated fl ow is held even when the power supply is OFF.
Electrical
Power supply voltage
12 to 24 VDC
±
10 %
Current consumption
25 mA or less
Protection
Polarity protection
Accuracy
Display accuracy
±
0.5 % F.S.
±
Minimum display unit (Ambient temperature at 25
°C)
Analogue output accuracy
±
0.5 % F.S. (Ambient temperature at 25
°C)
Repeatability
±
0.1 % F.S.
±
1 digit
Temperature characteristics
±
0.5 % F.S. (Ambient temperature: 0 to 50
°C, 25
°C standard)
Switch output
Output type
Select from NPN or PNP open collector output.
Output mode
Select from Hysteresis, Window comparator, Accumulated output, Accumulated pulse output,
Error output, or Switch output OFF modes.
Switch operation
Select from Normal or Reversed output.
Max. load current
80 mA
Max. applied voltage (NPN only)
30 VDC
Internal voltage drop (Residual voltage)
NPN output: 1 V or less (at load current of 80 mA), PNP output: 1.5 V or less (at load current of 80 mA)
Response time
∗
2
3 ms or less
Delay time
∗
2
Select from 0.00, 0.05 to 0.1 s (increment of 0.01 s), 0.1 to 1.0 s (increment of 0.1 s), 1 to 10 s (increment of 1 s), 20 s, 30 s, 40 s, 50 s, or 60 s.
Hysteresis
∗
4
Variable from 0
Protection
Short circuit protection
Analogue
output
∗
5
Output type
Voltage output: 1 to 5 V, 0 to 10 V (only when the power supply voltage is 24 VDC)
Current output: 4 to 20 mA
(0
l/
min to maximum value of the rated fl ow)
Impedance
Voltage output
Output impedance: 1 k
Ω
Current output
Maximum load impedance: 300
Ω
(at power supply voltage of 12 V), 600
Ω
(at power supply voltage of 24 VDC)
Response time
∗
2
50 ms or less
External input
∗
6
External input
Input voltage: 0.4 V or less (Reed or Solid state) for 30 ms or longer
Input mode
Select from Accumulated value external reset or Peak/Bottom value reset.
Sensor input
Input type
Voltage input: 1 to 5 VDC (Input impedance: 1 M
Ω
), Current input: 4 to 20 mA DC (Input impedance: 51
Ω
)
(0
l/
min to maximum value of the rated fl ow)
Connection method
Connector (e-CON)
Protection
Over voltage protection (Up to 26.4 VDC)
Display
Display mode
Select from Instantaneous fl ow or Accumulated fl ow.
Unit
∗
7
Instantaneous fl ow
l/
min, cfm (ft
3
/min)
Accumulated fl ow
L, ft
3
, L x 10
6
, ft
3
x 10
6
Display
range
Instantaneous fl ow
−25 to 525
l/
min
−50 to 1050
l/
min
−100 to 2100
l/
min
Accumulated fl ow
∗
9
0 to 999,999,999,990 L
Minimum
display unit
Instantaneous fl ow
1
l/
min
Accumulated fl ow
10 L
Display type
LCD
Number of displays
3-screen display (Main screen, Sub screen)
Display colour
1) Main screen: Red/Green, 2) Sub screen: Orange
Number of display digits
1) Main screen: 5 digits (7 segments), 2) Sub screen: 9 digits (7 segments)
Indicator LED
LED ON when switch output is ON. OUT1/2: Orange
Digital fi lter
∗
8
Select from 0.00, 0.05 to 0.1 s (increment of 0.01 s), 0.1 to 1.0 s (increment of 0.1 s), 1 to 10 s (increment of 1 s), 20 s, or 30 s.
Environmental
resistance
Enclosure
IP40
Withstand voltage
1000 VAC for 1 min between terminals and housing
Insulation resistance
50 M
Ω
or more (500 VDC measured via megohmmeter) between terminals and housing
Operating temperature range
Operating: 0 to 50
°C, Stored: −10 to 60
°C (No condensation or freezing)
Operating humidity range
Operating/Stored: 35 to 85 % RH (No condensation or freezing)
Standards
CE marking (EMC directive/RoHS directive)
Weight
Body
25 g (Excluding the power supply/output connection lead wire)
Lead wire with connector
+39 g
∗
1 Rated fl ow range of the applicable fl ow switch
∗
2 Value without digital fi lter (at 0.00 s)
∗
3 When using the accumulated value hold function, use the operating
conditions to calculate the product life, and do not exceed it. The maximum
access limit of the memory device is 1.5 million times. If the product is
operated 24 hours per day, the product life will be as follows:
•
5 min interval: life is calculated as 5 min x 1.5 million = 7.5 million min = 14.3 years
•
2 min interval: life is calculated as 2 min x 1.5 million = 3 million min = 5.7 years
If the accumulated value external reset is repeatedly used, the product life
will be shorter than the calculated life.
∗
4 If the flow fluctuates around the set value, be sure to keep a sufficient
margin. Otherwise, chattering will occur.
∗
5 Setting is only possible for models with analogue output.
∗
6 Setting is only possible for models with external input.
∗
7 Setting is only possible for models with the units selection function.
∗
8 The response time indicates when the set value is 90 % in relation to the step input.
∗
9 The accumulated fl ow display is the upper 6-digit and lower 6-digit (total of
12 digits) display. When the upper digits are displayed, x 10
6
lights up.
∗
Products with tiny scratches, marks, or display colour or brightness variations which
do not affect the performance of the product are verifi ed as conforming products.
For fl ow switch precautions and specifi c product precautions,
refer to the “Operation Manual” on the SMC website.
19