![SMC Networks JMHZ2-16D-X7500AC-KA Series Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/smc-networks/jmhz2-16d-x7500ac-ka-series/jmhz2-16d-x7500ac-ka-series_operation-manual_1299887018.webp)
- 17 -
4-5. Piping
Based on the dimensions of this product, connect the tube with an appropriate diameter to each air
supply port.
For the connection between this product and the air tubing coming out of the duAro arm, refer to the
Operation manual of the duAro.
4-6. Speed controller:
A push-lock type one-touch speed controller is fitted in each port to control speed in each direction of
travel.. Refer to
P. 18
for the product number of the speed controller.
!
Causion
1. Speed controller is provided with a retaining mechanism.
2. Make sure that the push-lock handle (hereinafter referred to as handle) is locked. When the orange
mark is visible, the speed controller is unlocked.
3. When the speed controller is unlocked, the set speed may change.
4. If the handle is pulled with force while the speed controller is unlocked, it may result in breakage.
When it is unlocked, do not pull the handle out with force.
5. To adjust the speed, start with the handle in the closed position, and then adjust by opening
gradually.
6. Too much rotation of the handle will cause damage.
The number of rotations of the handle is 4 from the fully closed position
!
Caution
1. Refer to the Fittings and Tubing Precautions (Best Pneumatics) for the speed controller with
one-touch fitting push lock type.
2. Before piping
Before piping is connected, it should be thoroughly flushed with air or washed to remove chips,
cutting oil and other debris from inside the pipe.
Handle
Unlocked state
Locked state
Orange mark