9
4) Do not use air containing mist and/or dust.
·
Air containing mist and/or dust may cause performance deterioration, and reduce the maintenance cycle.
·
Install a dryer (IDF series), air filter (AF/AFF series), and/or mist separator (AFM/AM series) to obtain clean
compressed air (air quality of Class 2.4.3, 2.5.3, 2.6.3 or higher according to ISO 8573-1: 2010 (JIS
B8392-1:2012) is recommended for operation.
5)
Controller, high voltage power supply module, bar and AC adapter are not resistant to lightening
surge.
1) Perform maintenance regularly and clean the emitters.
·
Check regularly that the product is not operating with
undetected failures.
·
The maintenance must be carried out by an operator
who has sufficient knowledge and experience.
·
If the product is used for an extended period with dust
present on the emitters, the product performance will be
reduced.
·
Maintenance detection function is installed to
IZT41 and IZT42. When the emitter contamination is
detected, clean the emitter.
·
In cases where the maintenance detection function is not used on the IZS41 or IZS42 or IZT40 is used,
perform neutralizing performance test and set maintenance cycle for periodic cleaning.
·
Emitter contamination level is different depending on the installation environment and supply pressure.
Refer to section "9. Maintenance" for details.
·
If the performance is not recovered after cleaning, it is possible that emitters are worn. Replace the emitter
cartridge.
2) Be sure to remove power supply and air supply to the controller, high voltage power supply module
and bar before cleaning the emitter or replacing the emitter cartridge.
·
Never touch the emitter with the power supplied to the controller, high voltage power supply module or bar.
Electric shock may cause injury.
·
If the emitter cartridge is removed while air is supplied, the emitter cartridge jumps out by compressed air.
Replace the emitter cartridge after discharging the supply air.
·
If emitter cartridges are not securely mounted to the bar, they may eject or release when air is supplied to the
product.
·
Securely mount or remove the emitter cartridges referencing the instructions shown below.
·
Securely mount or remove the emitter cartridges with hands and do not use tools.
(Tightening torque: 0.2 to 0.3 Nm)
3) Do not disassemble or modify the product.
·
Disassembling or modifying the product may cause product, electric shock or fire. The product will not be
guaranteed if it is disassembled and/or modified.
4) Do not operate the product with wet hands.
·
Never operate the product with wet hands. It may cause electric shock or other accidents.
Warning
Maintenance / Check
(1)Rotate the cartridge
90 degrees in the
counter-clockwise
direction.
(2) Pull to remove.
(1) Insert the cartridge into the bar
so that the longer side
of the cartridge is
mounted at a right
angle to the bar.
(2) Rotate the emitter cartridge for
90 degrees in the clockwise
direction, and match the markings
on the bar and on the
cartridge to fix.
Removal of the emitter
cartridge
Mounting of the emitter
cartridge
・
This product contains a high voltage
generation circuit. When performing
maintenance inspection, be sure to
confirm that the power supply to the
ionizer is turned off.
・
Never disassemble or modify the product,
as this can cause loss of product
functionality, and there is also a risk of
electric shock and earth leakage.
High voltage caution