49
2) Setting IZT41 and IZT42
(Default condition)
Frequency setting
: 30Hz
Key lock
: OFF
Built-in sensor
: ON
Maintenance detection level
: MIDDLE
Note 54) In Channel selection mode, frequency set mode, offset voltage adjustment mode, balance control
selection mode or maintenance detection level selection mode, the selected bar (high voltage power supply
module) moves on to the ion generation stop mode by pressing
▼ and ▲
button simultaneously for 2 s or
longer and stops the ion generation. (Operation is not possible while the key lock is ON or externally input
signal is ON)
To release, press the S button once or turn the power off and on again. Refer to[ 4-4-8. ion
generation stop mode] for further details.
[Channel selection mode]
Select the CH number for setting and display. When multiple high voltage power supply modules are
connected, switch the CH for setting and display. Refer to 4-4-2. Channel selection mode for details.
Note 54)
[Frequency set mode]
Set the ion generation
frequency of the bar
selected by "Channel
selection mode”.
Refer to 4-4-3. Frequency
set mode for details.
Note 54)
[ Key-lock setting
mode]
Perform a key-lock setting.
Refer to 4-4-7. Key-lock
set mode for details.
[ Balance control
selection mode ]
Select ON/ OFF of the
balance control by the sensor
built in the high voltage power
supply module selected in
"Channel selection mode"
Refer to 4-4-5. Balance
control selection mode for
details. Note 54)
[Offset voltage
adjustment mode]
Adjust the offset voltage of
the bar selected by ”CH
selection mode".
Refer to "4-4-4.
Adjustment of Offset
Voltage" for details.
Note 54)
[ Emitter contamination
detection level selection
mode]
Set the contamination
detection level of the high
voltage power supply module
emitter selected by "Channel
selection mode".
Refer to 4-4-6. Emitter
contamination detection level
selection mode for details.
Note 54)
[Channel selection mode]
Press S button
once
Press S button
once
Press S button
once
Press S button
once
Press S button for
3 sec. or longer
Press the
△
button and S
button at the same time for
2 seconds or longer.
Power is supplied.
Press S button
once
Press S button
once
Содержание IZT40 Series
Страница 1: ...Document No IZ OMT0049 B PRODUCT NAME Ionizer MODEL Series IZT40 41 42series...
Страница 73: ...High voltage power supply module IZTP40 IZTP41 When DIN rail mounting bracket IZT40 B2 is used...
Страница 74: ...High voltage power supply module IZTP42 When DIN rail mounting bracket IZT40 B3 is used...