39
3-3-2. IZT41
、
IZT42
1)During operation
Note 22) It takes 3 seconds to operate after the power is on.
Note 23) Press the controller button for 2 seconds or longer to stop the ion generation. To release, press the S button once or turn the power off and on again.
Note 24) When the ion generation is stopped by the controller button, the signals input from the outside are disabled.
After the release of the button, externally input signal becomes effective. To release, press the S button once or turn the power off and on again.
Note 25)
5P
flashes.
Note 26) ION/HV of the bar (high voltage power supply module) corresponding to the externally input signals turns off.
Note 27) The bar corresponding to externally input signals (high voltage power supply module) stops ion generation.
Note 28) Selected bar (high voltage power supply module) ION/HV to display is turned off.
Note 29) Selected bar (high voltage power supply module) stops the ion generation.
Display
Status
Operation
In
p
u
t
Power 24 VDC
―
Ion generation stop
External input signal
―
Controller button
▲
/
▼
/ S button
―
O
u
tp
u
t
Maintenance detection signal
(Normally OFF)
―
Error signal
(Normally ON)
―
Maintenance (green)
NDL
CH display
High voltage power supply
module disconnected
Frequency
Ions are generated (green)
ION/HV
Incorrect high voltage (red)
Hz
ION BALANCE
―
Ion generating status
Built-in sensor (green)
SNSR
Key-lock (green)
KEY
D
is
p
la
y
CH display
Selected CH to display
CH
CH display
CH which display is not
selected
Product type
IZTP41(green)
IZTP42(blue)
DAC/AC
Power
ON
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
1Hz
Ion generation stop input.
External input signal.
Press and hold
無効
有効
ON
OFF
ON
OFF
Power
OFF
Power
ON
ON
OFF
ON
Ion generation
stop input.
Operation
button input.
▲+▼
button
ON
OFF
2s or longer
Ion generation
stop release.
Operation
button input.
S button
ON
Note 23)
Note 23)
Note 24)
Note 22)
ON
OFF
ON
OFF
ON
OFF
1Hz
Note 25)
Note 27)
Note 29)
Note 26)
Note 28)
Generate
Stop
Display
Status
Operation
In
p
u
t
Power 24 VDC
―
Ion generation stop
External input signal
―
Controller button
▲
/
▼
/ S button
―
O
u
tp
u
t
Maintenance detection signal
(Normally OFF)
―
Error signal
(Normally ON)
―
Maintenance (green)
NDL
CH display
High voltage power supply
module disconnected
Frequency
Ions are generated (green)
ION/HV
Incorrect high voltage (red)
Hz
ION BALANCE
―
Ion generating status
Built-in sensor (green)
SNSR
Key-lock (green)
KEY
D
is
p
la
y
CH display
Selected CH to display
CH
CH display
CH which display is not
selected
Product type
IZTP41(green)
IZTP42(blue)
DAC/AC
Note 23)
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
無効
有効
ON
OFF
ON
OFF
Press and hold
ON
Power
OFF
Power
ON
1Hz
Ion generation
stop input.
Operation
button input.
▲+▼
button
ON
OFF
2s or longer
Note 23)
Note 24)
Note 22)
ON
OFF
ON
OFF
ON
OFF
1Hz
Note 25)
Note 29)
Note 28)
ON
Ion generation
stop input.
Operation
button input.
▲+▼
button
Ion generation
stop input.
External
input signal.
ON
2s or longer
2s or longer
Note 23)
Note 24)
Ion generation
stop release.
Operation
button input.
S button
ON
ON
Ion generation
stop input.
Operation
button input.
▲+▼
button
Ion generation
stop input.
External
input signal.
OFF
1Hz
Note 25)
Note 26,28)
Note 27,29)
Generate
Stop
Press and hold
Press and hold
Содержание IZT40 Series
Страница 1: ...Document No IZ OMT0049 B PRODUCT NAME Ionizer MODEL Series IZT40 41 42series...
Страница 73: ...High voltage power supply module IZTP40 IZTP41 When DIN rail mounting bracket IZT40 B2 is used...
Страница 74: ...High voltage power supply module IZTP42 When DIN rail mounting bracket IZT40 B3 is used...