background image

 Z_ISE40A-TF2Z052EN

 

Page 1 of 3 

 

 

Instruction Manual        
Digital Pressure Switch 
Series ZSE40A(F) / ISE40A

 

 
 
 
 
 
 
 

 

 

The intended use of this digital pressure switch is to measure, monitor 
and display pressure and to provide an output signal.

 

1 Safety Instructions 

These safety  instructions  are  intended  to  prevent  hazardous situations 
and/or  equipment  damage.  These  instructions  indicate  the  level  of 
potential hazard with the labels of “Caution,” “Warning” or “Danger.” 
They are all important notes for safety and must be followed in addition 
to International  Standards (ISO/IEC)

 *1)

, and other safety regulations. 

*1)

 ISO 4414: Pneumatic fluid power - General rules relating to systems.  

ISO 4413: Hydraulic fluid power - General rules relating to systems. 
IEC 60204-1: Safety of machinery - Electrical equipment of machines.        
(Part 1: General requirements) 
ISO  10218-1:  Robots  and  robotic  devices  -  Safety  requirements  for 
industrial robots - Part 1: Robots. 

  Refer  to  product  catalogue,  Operation  Manual  and  Handling 

Precautions for SMC Products for additional information. 

  Keep this manual in a safe place for future reference. 

 

 

Caution 

Caution indicates a hazard with a low level of risk which, if 
not avoided, could result in minor or moderate injury. 

 

Warning 

Warning indicates a hazard with a medium level of risk 
which, if not avoided, could result in death or serious injury. 

 

Danger 

Danger indicates a hazard with a high level of risk which, if 
not avoided, will result in death or serious injury. 

Warning 

 

Always  ensure  compliance  with  relevant  safety  laws  and 
standards. 

  All work must be carried out in a safe manner by a qualified person in 

compliance with applicable national regulations. 

  This  product  is  class  A  equipment  intended  for  use  in  an  industrial 

environment.  There  may  be  potential  difficulties  in  ensuring 
electromagnetic compatibility in other environments due to conducted 
or radiated disturbances. 

Otherwise electric shock, malfunction or product damage can result. 

  Refer  to  the  operation  manual  on  the  SMC  website  (URL: 

https://www.smcworld.com

) for more safety instructions. 

  Special  products  (-X)  might  have  specifications  different  from  those 

shown  in  the  specifications  section.  Contact  SMC  for  specific 
drawings. 

 

 

 

 

 

 

 

 

2 Specifications 

2.1  General specifications 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.2  Piping / Weight specifications 

Model No.

 

01

 

N01

 

W1

 

WF1

 

M5

 

C4

 

C6

 

Port size

 

R1/8

 

(M5 

female)

 

NPT1/8

 

(M5 

female)

 

Rc1/8

 

G1/8

 

M5

 

female

 

One-

touch 

fitting 

φ

4

 

One-

touch 

fitting 

φ

6

 

M

a

te

ri

a

l

 

Sensor 

 

Silicone

 

Piping 
port

 

C3602

 

(electroless 

nickel plating)

 

O-ring: HNBR

 

ZDC2

 

O-ring: HNBR

 

ZDC2, POM, 

SUS304, C3604

 

(electroless nickel 

plating)

 

O-ring: HNBR, NBR

 

Weight

 

78 g

 

79 g

 

97 g

 

97 g

 

104 g

 

101 g

 

101 g

 

 

3 Name and function of parts 

 

 
Indicator LED (Orange LED): Displays the switch output condition. 
LCD display:   Displays the current status of pressure, setting mode and 

error code.  

 

Four display modes can be selected: display always in 
red or green, or display changing from green to red, or 
red to green, according to the output status. 

 button (UP):  

Selects  the  mode  or  increases  the  ON/OFF  set 
value.  Press  this  button  to  change  to  the  peak 
display mode. 

 button  (DOWN):  Selects  the  mode  or  decreases  the  ON/OFF  set 

value.  Press  this  button  to  change  to  the  bottom 
display mode. 

 button (SET):   Press this button to change to another mode and to 

set a value. 

 
 
 
 

4 Installation 

4.1  Installation 

Warning 

  Do not install the product unless the safety instructions have been read 

and understood. 

  When the product is to be mounted in a place where water and dust 

splashes  occur,  insert  a  tube  (O.D 

φ

4  mm,  I.D 

φ

2.5  mm)  into  the 

atmospheric vent port of the product. 

 

4.1.1 Mounting with bracket 

 

Mount the bracket to the product with the mounting screws M3 x 5L (2 
pcs.) or M4 x 5L (2 pcs.) supplied, then set the product in the required 
position.

 

: The required tightening torque is 0.5 to 0.7 N•m for the M3 set screws 

and 1.4 to 1.6 N•m for the M4 set screws. 

 

Bracket A or D (Part No.: ZS-24-A / ZS-24-D)           

 

[01 / N01 type] 

 

             [W1 / WF1 type] 

       

 

          

For products with M8 (3 pin) connector, be sure to reserve a space for 
the lead wire and connector.

 

 

4 Installation (continued) 

Bracket B (Part No.: ZS-24-B)           

 

 

 

4.1.2 Mounting with panel mount adapter 

  Products with M8 (3 pin) connector cannot be panel mounted. 

  Panel mount adapter (Part No.: ZS-35-C / ZS-35-D) 

    Panel mount a Front protective cover (Part No.: ZS-35-F / -G). 

 

 

: The panel mount adapter can be rotated through 90 degrees for mounting. 

4.2  Environment 

Warning 

  Do not use in an environment where corrosive gases, chemicals, salt 

water or steam are present. 

  Do not use in an explosive atmosphere. 

  Do not expose to direct sunlight. Use a suitable protective cover. 

  Do  not  install  in  a  location  subject  to  vibration  or  impact.  Check  the 

product specifications. 

  Do not mount in a location exposed to radiant heat. 

  Do not use the product in a place where electrical static charge will be 

a problem. It can cause the error and damage to the system. 

 

4.3  Piping 

Caution 

  Before piping make sure to clean up chips, cutting oil, dust etc. 

  When  installing  piping  or  fittings,  ensure  sealant  material  does  not 

enter inside the port. When using seal tape, leave 1 thread exposed 
on the end of the pipe/fitting.  

  Tighten fittings to the specified tightening torque. 

 

4.3.1 Connection using screw type fitting 

  Connect suitable piping to the port. 

  Hold the hexagon part of the piping port and fix. The required tightening 

torque is 7 to 9 N•m. 

  When using an M5 female fitting confirm the fitting specification. 

 

ORIGINAL INSTRUCTIONS 

Model No. 

ZSE40A  

(vacuum) 

ZSE40AF  

(compound) 

ISE40A 

(positive) 

Rated pressure range 

0 to -101.3 

kPa 

-100.0 to 

100.0 kPa

 

-0.100 to 

1.000 MPa

 

Set pressure range 

10.0 to -

105.0 kPa 

-105.0 to 

105.0 kPa

 

-0.105 to 

1.050 MPa

 

Withstand pressure 

500 kPa 

500 kPa 

1.5 MPa 

Minimum display unit 

0.1 kPa 

0.1 kPa 

0.001 MPa 

Applicable fluid 

Air, inert gases and incombustible gases 

Power supply voltage 

12 to 24 VDC ±10%, ripple (p-p) 10% or less 

(protected against reverse connection) 

Current consumption 

45 mA or less 

Switch output 

NPN or PNP open collector 2 outputs 

 

Max. load current 

80 mA 

Max. applied 
voltage 

28 V (NPN output) 

Residual voltage 

1 V or less (at 80 mA load current) 

Response time 

2.5 ms or less 

(with anti-chatter function: 20, 100, 500, 1000 

or 2000 ms) 

Protection 

Short circuit protection 

Repeatability 

±0.2% F.S. ±1 digit 

Hysteresis 

0 to variable 

A

n

a

lo

g

u

e

 o

u

tp

u

V

o

lt

a

g

e

  Output voltage 

(rated pressure) 

1 to 5 V ±2.5% F.S. 

0.6 to 5 V 

±2.5% F.S. 

Linearity 

±1% F.S. 

Output 
impedance 

Approx. 1 k

 

C

u

rr

e

n

Output current 
(rated pressure) 

4 to 20 mA ±2.5% F.S. 

2.4 to 20 mA  

±2.5% F.S. 

Linearity 

±1%F.S. 

Load 
impedance 

Max. load impedance: 300 

 (at 12 VDC) 

 

 

    600 

 (at 24 VDC) 

Min. load impedance:  50 

 

Auto-shift input 

Non-voltage input (reed or solid state),  

Low level 0.4 V or less, input time 5 ms min. 

Display 

3½ digits, 7-segment, dual-colour display 

(red/green) 

Display accuracy 

±2% F.S. ±1 digit (at 25 ±3 

°

C) 

Indicator LED 

LED is ON when output is ON   

OUT: Orange 

E

n

v

ir

o

n

m

e

n

Enclosure 

IP65 

Operating 
temperature range 

Operation: -5 to 50 

°

C, Storage: -10 to 60 

°

(no condensation or freezing) 

Operating humidity 
range 

Operation, Storage: 35 to 85% RH (no 

condensation) 

Withstand voltage 

1000 VAC, 1 minute between terminals and 

housing 

Insulation resistance 

50 M

 or more at 500 VDC between 

terminals and housing 

UL Temperature rating 

Surrounding air temperature rating: 

Maximum 50 

o

Temperature 
characteristics 

±2% F.S. (at 25 

°

C reference) 

Lead wire 

Oil resistant vinyl cabtyre cable 
5 cores    

φ

3.5, 2 m 

Conductor:  

0.15 mm

2

 (AWG26) 

O.D. of insulator:   0.95 mm 

 

 

 

 

Отзывы: