Specifi cations

Model

ZSE20

 (Vacuum pressure)

ZSE20F 

(Compound pressure)

ISE20

 (Positive pressure)

Applicable fluid

Air, Non-corrosive gas, Non-flammable gas

Pressure

Rated pressure range

0.0 to −101.0 kPa

−100.0 to 100.0 kPa

−0.100 to 1.000 MPa

Set pressure range

10.0 to −105.0 kPa

−105.0 to 105.0 kPa

−0.105 to 1.050 MPa

Smallest settable increment

0.1 kPa

0.001 MPa

Withstand pressure

500 kPa

1.5 MPa

Electrical

Power supply voltage

12 to 24 V DC 

±

10 %, Ripple (p-p) 10 % or less

Current consumption

25 mA or less

Protection

Polarity protection

Accuracy

Display accuracy

±

2 % F.S. 

±

1 digit (Ambient temperature of 25 

±

3 °C)

Repeatability

±

0.2 % F.S. 

±

1 digit

Temperature characteristics

±

2 % F.S. (25

 

°C reference)

Switch output

Output type

NPN or PNP open collector 1 output

Output mode

Hysteresis mode, Window comparator mode, Error output, Output OFF

Switch operation

Normal output, Reversed output

Maximum load current

80 mA

Maximum applied voltage (NPN only)

28 V

Internal voltage drop (Residual voltage)

1 V or less (with load current of 80 mA)

Delay time 

Note 1)

1.5 ms or less (with anti-chattering function: 20, 100, 500, 1000, 2000, 5000 ms)

Hysteresis

Hysteresis mode

Variable from 0 

Note 2)

Window comparator mode

Short circuit protection

Yes

Display

Unit 

Note 3)

MPa, kPa, kgf/cm

2

, bar, psi, InHg, mmHg

MPa, kPa, kgf/cm

2

, bar, psi

Display type

LCD

Number of screens

3-screen display (Main screen, Sub screen x 2)

Display colour

1) Main screen: Red/Green
2) Sub screen: Orange

Number of display digits

1) Main screen: 4-digit (7-segment)
2) Sub screen: 4-digit (Upper 1-digit 11-segment, 7-segment for other)

Indicator light

Lights up when switch output is turned ON. OUT1: Orange

Digital filter

 

Note 4)

0, 10, 50, 100, 500, 1000, 5000 ms

Environment

Enclosure

IP40

Withstand voltage

1000 V AC for 1 minute between terminals and housing

Insulation resistance

50 M

Ω

 or more (500 V DC measured via megohmmeter) between terminals and housing

Operating temperature range

Operating: −5 to 50

 

°C, Stored: −10 to 60

 

°C (No freezing or condensation)

Operating humidity range

Operating/Stored: 35 to 85 % RH (No condensation)

Standards

CE, RoHS

Length of lead wire with connector

2 m

Note 1) Value without digital filter (at 0 ms)
Note 2)  If the applied pressure fluctuates around the set value, the hysteresis must be set to a value more than the amount of fluctuation or chattering will occur.
Note 3) This setting is only available for models with the unit selection function. Only MPa or kPa is available for models without this function.
Note 4) The response time indicates when the set value is 90 % in relation to the step input.

Piping Specifications and Weights

Model

M5

01

N01

Port size

M5 x 0.8

R 1/8

NPT 1/8

Materials of 
parts in contact 
with fluid

Sensor pressure receiving area

Silicon

Piping port (Common)

PBT, CB156, Heat resistant PPS, O-ring: HNBR

Piping port

C3604 (Electroless nickel plating), Stainless steel 304, NBR

Weight

Body

22 g

30 g

Lead wire with connector

+35 g

When optional parts are required separately, use the following part numbers to place an order.

Description

Part number

Note

Bracket A

ZS-46-A1

Tapping screw: Nominal size 3 x 8 L (2 pcs.)

Bracket B

ZS-46-A2

Tapping screw: Nominal size 3 x 8 L (2 pcs.)

Panel mount adapter

ZS-46-B

Panel mount a Front protection cover

ZS-46-D

Lead wire with connector

ZS-46-3L

3 cores, 2 m

Front protection cover

ZS-27-01

R 1/8 Piping adapter

ZS-39-N1

NPT 1/8 Piping adapter

ZS-39-N2

Cable Specifications

Conductor area

0.15 mm

(AWG26)

Insulator

Outside diameter

1.0 mm

Colour

Brown, Blue, Black (3 cores)

Sheath

Finished outside diameter

Ø 3.4

Options/Part Numbers

6

3-Screen Display

High-Precision Digital Pressure Switch  

Series

 ZSE20(F)/ISE20

Содержание ISE20

Страница 1: ...of setting Release the button after is displayed on the right side sub screen Pressing the and buttons for a minimum of 1 second will make the set value threshold value the same as the current pressure value Whilecheckingthemeasuredvalue Measured value Current pressure value Main screen settingispossible Label Display item Set value Threshold value Sub screen Visualisation of Setting Items Setvalu...

Страница 2: ...etting is possible while checking the measured value Set value Threshold value Hysteresis value Bottom value Peak value Improved Operability The sub screen can be switched by pressing up down buttons Measuredvalue Currentpressurevalue Main screen Set value Threshold value Sub screen Right side Label Display item Sub screen Left side Current model ZSE20 F ISE20 Displays in turn Normal output Setval...

Страница 3: ...merical value 3 Setting Modes Setting mode can be selected according to the purpose 3 Step Setting Mode Completion of Setting Completion of Setting Completion of Setting Simple Setting Mode Function Selection Mode Press the button once Press the button between 1 and 3 seconds Press the button between 3 and 5 seconds Settings Threshold value setting or Hysteresis value setting Simple Higher functio...

Страница 4: ...put Reversed output Reversed output Peak value Bottom value Peak Bottom value Label Peak Peak value Label Bottom Bottom value Peak value Bottom value 앬Compact 17 5 mm shorter When M5 female thread is used 앬Lightweight 21 g lighter When M5 female thread is used 13 g lighter When R 1 8 is used 앬Secret code setting function The key locking function keeps unauthorised persons from tampering with butto...

Страница 5: ...es Output Piping Withstand pressure Smallest settable increment Rated pressure range Set pressure range 0 105 to 1 050 MPa 1 5 MPa 0 001 MPa 105 0 to 105 0 kPa 500 kPa 0 1 kPa NPN or PNP open collector 1 output M5 Female thread R 1 8 NPT 1 8 10 0 to 105 0 kPa 500 kPa 0 1 kPa 100 kPa 100 kPa 0 100 0 to 100 0 kPa 1 MPa 0 0 1 MPa 100 kPa 0 100 to 1 000 MPa ISE20 Positive pressure ZSE20 Vacuum pressur...

Страница 6: ...ction function M SI unit only Note P With unit selection function Initial value psi Note Fixed unit kPa MPa Piping specification Symbol Description M5 M5 Female thread 01 R 1 8 N01 NPT 1 8 Option 3 Symbol Operation Manual Calibration certificate 앪 Y K 앪 앪 T 앪 Option 1 Symbol Description Without lead wire L Lead wire with connector Lead wire length 2 m ZS 46 3L Option 2 Symbol Description None A1 B...

Страница 7: ...hstand voltage 1000 V AC for 1 minute between terminals and housing Insulation resistance 50 MΩ or more 500 V DC measured via megohmmeter between terminals and housing Operating temperature range Operating 5 to 50 C Stored 10 to 60 C No freezing or condensation Operating humidity range Operating Stored 35 to 85 RH No condensation Standards CE RoHS Length of lead wire with connector 2 m Note 1 Valu...

Страница 8: ...asurement Bottom value indication function Can retain the minimum pressure value displayed during measurement Keylock function Selectable secret code The key board can be locked to prevent any incorrect function of the operation switch Zero clear function The pressure display can be set at zero when the pressure is open to the atmosphere Error indication function This function is to display error ...

Страница 9: ...5 2 A N01 M5 01 Dimensions Z ISE20 F Piping specification M5 Female thread R 1 8 NPT 1 8 Piping specification Port size A 01 R 1 8 Width across flats 10 N01 NPT 1 8 Width across flats 12 8 3 Screen Display High Precision Digital Pressure Switch Series ZSE20 F ISE20 ...

Страница 10: ...nting in four orientations Note Bracket configuration allows mounting in four orientations A1 A2 Dimensions Note When using the bracket B install it by taking the dimensions of the piping part into consideration With Bracket Z ISE20 F Option 2 Bracket A Optional part number ZS 46 A1 Bracket B Optional part number ZS 46 A2 9 Series ZSE20 F ISE20 ...

Страница 11: ...1 11 20 2 34 5 33 5 33 5 42 4 R4 5 47 8 50 8 R4 5 Dimensions Panel mount adapter Z ISE20 F Option 2 B Panel mount adapter Optional part number ZS 46 B D Panel mount adapter Front protection cover Optional part number ZS 46 D 10 3 Screen Display High Precision Digital Pressure Switch Series ZSE20 F ISE20 ...

Страница 12: ... 24 or more 31 0 0 4 24 or more 31 x n pcs 3 5 x n pcs 1 4 x R 2 o r l e s s 31 0 0 4 Dimensions Multiple 2 pcs or more secure mounting Horizontal Panel mount example Horizontal Panel mount example Vertical Vertical Panel fitting dimensions Individual mounting 11 Series ZSE20 F ISE20 ...

Страница 13: ...lue or more Turns ON at the set value or less Switch ON Switch OFF 0 0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 MPa Measuredvalue Measuredvalue Turns ON at the set value or less Turns ON at the set value or more Differencebetween ONandOFF 0 45 0 50 0 55 0 60 MPa Switch ON Switch OFF Difference between ON 쑺 OFF and OFF 쑺 ON 0 40 0 45 0 50 0 55 MPa Switch ON Switch OFF Difference between OFF 쑺 ON and ON 쑺 OFF 0 ...

Страница 14: ...n the range of 5 of the read value The scattering of the indicated value can be eliminated Suction Verification Formula for Obtaining the Set Value This function constantly detects and updates the maximum minimum pressure when the power is supplied and allows to hold the maximum minimum pressure value The held value is maintained even if the power supply is cut When the buttons are simultaneously ...

Страница 15: ...SE20F compound pressure will have different setting and display resolution when the unit is set to MPa I Power saving mode F80 Power saving mode can be selected It shifts to the power saving mode without button operation for 30 seconds It is set to the normal mode Power saving mode is OFF when ex factory During power saving mode ECo will flash in the sub screen and the operation light is ON only w...

Страница 16: ...pment in conjunction with atomic energy railways air navigation space shipping vehicles military medical treatment combustion and recreation or equipment in contact with food and beverages emergency stop circuits clutch and brake circuits in press applications safety equipment or other applications unsuitable for the standard specifications described in the product catalogue 3 An application which...

Отзывы: