background image

Pressure Setting

 

 

Warning 

(1)  Set within the display pressure range of the scale plate. If it is set outside of the pressure display 

range, it may cause operation failure or setting deviation. 

Caution 

(1)  Use a screwdriver of a size suitable for the groove of the adjustment screw. 
(2)  The switch setting display indicator shows the pressure when the switch is turned off. 
(3)  Pressure  when  the  switch  is  ON  is  the  pressure  in  when  hysteresis  is  added  to  the  indicated 

pressure.   

(4)  The  pressure  displayed  by  the  indicator  is  a  guideline.  Measure  the  pressure  correctly  using  a 

pressure gauge.   

 

Maintenance 

Warning 

(1)  Maintenance should be performed according to the procedure indicated in the Operation Manual. 

If handled improperly, malfunction and damage of machinery or equipment may occur. 

(2)  Perform regular inspections and confirm normal operation. 

Otherwise it may be impossible to guarantee safety due to unexpected malfunction or erroneous 
operation. 

(3)  Do not touch the internal wiring during energizing. 

 

 

There is a risk of electric shock by contact with the product that is energized. 
Turn OFF the power supply before wiring. 

(4)  Make sure to wear safety goggles for regular maintenance. 
(5)  Make  sure  to  confirm  that  no  pressure  is  applied  to  this  product  and  that  electrical  cables  are 

disconnected before performing maintenance. 

(6)  After  maintenance,  confirm  that  the  product  satisfies  specific  functions  and  no  external  leakage 

occurs before operating it. 

(7)  Maintenance work 

If handled improperly, compressed air can be dangerous. Maintenance should be performed by a 
knowledgeable and experienced person. 

(8)  Drain flushing 

Compressed  air  containing  too  much  condensate  leads  to  malfunction.

 

Air  filters  installed  on 

airlines,  etc.,  requires  periodic  discharge  of  the  drain  to  make  sure  that  the  drain  does  not  flow 
downstream. Check the filter element periodically and replace it with a new one if necessary. 

(9)  Removal of equipment, and supply/exhaust of compressed air. 

When  components  are  removed,  first  confirm  that  measures  are  in  place  to  prevent  workpieces 
from dropping, run-away equipment, etc. Then, cut off the supply pressure and electric power, and 
exhaust  all  compressed  air  from  the  system  using  the  residual  pressure  release  function.  When 
re-starting the product, make sure that the liquid sudden blow prevention is applied. 

(10) Caution for use in an interlock system If using in an interlock circuit, provide a double interlock in 

vessel of failure, and perform regular checks to confirm proper operation.

 

(11) When  installing  the  products,  allow  access  for  maintenance.  It  may  not  be  possible  to  perform 

maintenance checks if there is not enough space.

 

 

-7- 

Содержание IS10E-20-D

Страница 1: ...tch with T Spacer Pressure Switch with L Piping Adapter Pressure Switch with Piping Adapter MODEL Series Product Number IS10M 20 30 40 50 60 1 6 L P Z D IS10T 20 30 40 50 60 F N 6 L P Z D IS10L 20 30...

Страница 2: ...3 Standard Specifications 8 9 4 Electric circuit 10 5 Relation between Pressure setting and operating pressure 10 6 How to Order 11 14 7 Structural Drawing 15 8 Type of scale 15 9 Pressure Setting Me...

Страница 3: ...failure when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectly The assembl...

Страница 4: ...the product 3 Prior to using SMC products please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products 2 Vacuum pads are excluded from this...

Страница 5: ...the product after carefully reading and understanding the operation manual 2 Do not drop or apply impact during transportation or installation It will cause damage to the product or operation failure...

Страница 6: ...ing moment other than the weight of the product itself External piping needs to be supported separately as it may cause breakage Non flexible piping like steel tube is susceptible to excessive moment...

Страница 7: ...ct protection box connect the lead wire indicating SWITCH on the contact protection box and the lead wire from the switch The lead length between the switch body and the contact protection box should...

Страница 8: ...pplied to this product and that electrical cables are disconnected before performing maintenance 6 After maintenance confirm that the product satisfies specific functions and no external leakage occur...

Страница 9: ...x operating current Switch Characteristics Hysteresis Air 5 to 60 o C with no freezing 1 0MPa 0 7MPa 0 1MPa to 0 4MPa 24VAC DC or less 50mA 48VAC DC or less 40mA 100VAC DC or less 20mA Equivalent to I...

Страница 10: ...ess 50mA 48VAC DC or less 40mA 100VAC DC or less 20mA Equivalent to IP40 Model Max operating pressure Hysteresis Switch Characteristics Max operating current IS10E 20 D IS10E 30 D IS10E 40 D IS10E 50...

Страница 11: ...ic circuit 5 Relation between Pressure setting and operating pressure 10 0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 1 0 2 0 3 0 4 0 5 0 6 Operating pressure MPa Set pressure scale MPa ON pressure OFF pressure Hy...

Страница 12: ...e selected alphabetically a to d Note 2 Set pressure range of 6 psi 0 2 to 0 6 MPa 30 to 90 psi Note 3 Smaller face to face type cannot be mounted on the spacer with the bracket at both ends Mount a s...

Страница 13: ...Nil 0 5 3 Z 5 Nil MPa P MPa psi dual scale Note 1 A semi standard product can be selected alphabetically a to c Note 2 Set pressure range of 6P is 0 2 to 0 6MPa 30 to 90psi 3 4 Semi standard a Set pre...

Страница 14: ...il MPa P MPa psi dual scale Nil R Note 1 A semi standard product can be selected alphabetically a to d Note 2 Set pressure range of 6P is 0 2 to 0 6MPa 30 to 90psi a Set pressure range b Lead wire len...

Страница 15: ...MPa P MPa psi dual scale Nil R Note 1 A semi standard product can be selected alphabetically a to d Note 2 Set pressure range of 6P is 0 2 to 0 6MPa 30 to 90psi a Set pressure range b Lead wire length...

Страница 16: ...usting screw Indicator Scale plate Lead wire Body Air flow PRESSURE SWITCH WITH T SPACER IS10T 20 D to IS10T 60 D IS10M 20 1 D to IS10M 60 1 D Air flow PRESSURE SWITCH WITH L PIPING ADAPTER IS10L 20 D...

Страница 17: ...ating the adjustment screw and setting the indicator to the figure on the scale Set pressure increases by rotating the adjustment screw clockwise Use a screwdriver of a size suitable for the groove of...

Страница 18: ...ssure 2 The lead wire cover has gouges or cracks 1 The lead wire has repeatedly been subject to bending or tensile force 1 Overcurrent was applied to the switch 1 Excessive impact has been applied to...

Страница 19: ...ld source provide a shield plate between the pressure switch and the source 1 1 Decrease the impact or use a solid state auto switch 5 The contact protection box has not been used The operating condit...

Страница 20: ...D 28 77 6 60 1 42 31 85 6 64 1 53 39 93 6 68 1 71 47 96 6 69 6 71 62 106 6 74 6 90 Model IS10M 20 D IS10M 30 D IS10M 40 D IS10M 50 D IS10M 60 D A B C D 10 6 83 8 66 3 42 12 6 91 8 70 3 53 14 6 97 8 7...

Страница 21: ...4 3 8 31 85 6 64 1 53 1 4 3 8 1 2 39 93 6 68 1 71 1 4 3 8 1 2 3 4 47 96 6 69 6 71 3 8 1 2 3 4 62 106 6 74 6 90 Model IS10 20 D IS10 30 D IS10 40 D IS10 50 D IS10 60 D Port size A B C D 1 8 1 4 28 77...

Страница 22: ...D 21 Port size A B C D E F 1 8 1 4 3 8 24 77 8 60 3 42 24 1 4 3 8 1 2 27 85 8 64 3 53 30 1 4 3 8 1 2 3 4 30 93 8 68 3 71 36 3 4 36 1 46 3 4 39 46 1 1 4 1 1 2 42 63 9 5 106 8 74 8 90 31 96 8 69 8 71 8...

Страница 23: ...cover Oct 2021 4 14 1 Sotokanda Chiyoda ku Tokyo 101 0021 JAPAN Tel 81 3 5207 8249 Fax 81 3 5298 5362 URL https www smcworld com Note Specifications are subject to change without prior notice and any...

Отзывы: