Precautions for Design 

Warning 

(1)  Keep the load/resistance within the specified range. 

Operation  outside  of  the  specification  range  may  cause  damage  to  the  product  or  operation 
failure. 

(2)  Air is the applicable fluid for this product. Please contact us when fluids other than air are used. 

Usage of inapplicable fluids may cause fluid leakage or malfunction. 

(3)  Use within the specified voltage and current. 

Use  of  a  voltage  or  current  outside  of  the  specifications  can  cause  malfunction,  damage  to  the 
switch, electric shock or fire. 
When the load capacity of the motor is large, use a magnet switch as well as relay. 

(4)  Not suitable for vacuum pressure area.   

If it is operated with vacuum pressure, it may cause malfunction.   

(5)  This product uses a reed switch. If the chattering of the output signal is a problem, choose a solid 

state type pressure switch or adjust by PLC. 

 

Installation

 

Warning 

(1)  Mount the product after carefully reading and understanding the operation manual. 
(2)  Do not drop or apply impact during transportation or installation. 

It will cause damage to the product or operation failure. 

(3)  Avoid applying vibration to the product. 

If the product is subject to vibration, it can cause a damage or a malfunction. 

(4)  Do not use in humid or humid areas. 

It will cause damage to the product or malfunction. 

(5)  Shield from ultra violet light and radiation with protective cover.

 

(6)  Employ suitable protective measures in locations where there is contact with oil or welding spatter, 

etc. 

(7)  Check mounting conditions.

 

The product can be mounted either vertically or horizontally. 

 

(8)  Make sure to hold the product body when handling the product, and do not apply tensile force to 

the lead wire.   

It will cause damage to the product or malfunction. 

(9)  Avoid repeatedly bending or stretching the lead wire. 

Broken lead wires will result if bending stresses or tensile forces are applied to the lead wires. 
If the lead wire is damaged, causing the operation failure, replace the product with a new one. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

-4- 

Содержание IS10E-20-D

Страница 1: ...tch with T Spacer Pressure Switch with L Piping Adapter Pressure Switch with Piping Adapter MODEL Series Product Number IS10M 20 30 40 50 60 1 6 L P Z D IS10T 20 30 40 50 60 F N 6 L P Z D IS10L 20 30...

Страница 2: ...3 Standard Specifications 8 9 4 Electric circuit 10 5 Relation between Pressure setting and operating pressure 10 6 How to Order 11 14 7 Structural Drawing 15 8 Type of scale 15 9 Pressure Setting Me...

Страница 3: ...failure when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectly The assembl...

Страница 4: ...the product 3 Prior to using SMC products please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products 2 Vacuum pads are excluded from this...

Страница 5: ...the product after carefully reading and understanding the operation manual 2 Do not drop or apply impact during transportation or installation It will cause damage to the product or operation failure...

Страница 6: ...ing moment other than the weight of the product itself External piping needs to be supported separately as it may cause breakage Non flexible piping like steel tube is susceptible to excessive moment...

Страница 7: ...ct protection box connect the lead wire indicating SWITCH on the contact protection box and the lead wire from the switch The lead length between the switch body and the contact protection box should...

Страница 8: ...pplied to this product and that electrical cables are disconnected before performing maintenance 6 After maintenance confirm that the product satisfies specific functions and no external leakage occur...

Страница 9: ...x operating current Switch Characteristics Hysteresis Air 5 to 60 o C with no freezing 1 0MPa 0 7MPa 0 1MPa to 0 4MPa 24VAC DC or less 50mA 48VAC DC or less 40mA 100VAC DC or less 20mA Equivalent to I...

Страница 10: ...ess 50mA 48VAC DC or less 40mA 100VAC DC or less 20mA Equivalent to IP40 Model Max operating pressure Hysteresis Switch Characteristics Max operating current IS10E 20 D IS10E 30 D IS10E 40 D IS10E 50...

Страница 11: ...ic circuit 5 Relation between Pressure setting and operating pressure 10 0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 1 0 2 0 3 0 4 0 5 0 6 Operating pressure MPa Set pressure scale MPa ON pressure OFF pressure Hy...

Страница 12: ...e selected alphabetically a to d Note 2 Set pressure range of 6 psi 0 2 to 0 6 MPa 30 to 90 psi Note 3 Smaller face to face type cannot be mounted on the spacer with the bracket at both ends Mount a s...

Страница 13: ...Nil 0 5 3 Z 5 Nil MPa P MPa psi dual scale Note 1 A semi standard product can be selected alphabetically a to c Note 2 Set pressure range of 6P is 0 2 to 0 6MPa 30 to 90psi 3 4 Semi standard a Set pre...

Страница 14: ...il MPa P MPa psi dual scale Nil R Note 1 A semi standard product can be selected alphabetically a to d Note 2 Set pressure range of 6P is 0 2 to 0 6MPa 30 to 90psi a Set pressure range b Lead wire len...

Страница 15: ...MPa P MPa psi dual scale Nil R Note 1 A semi standard product can be selected alphabetically a to d Note 2 Set pressure range of 6P is 0 2 to 0 6MPa 30 to 90psi a Set pressure range b Lead wire length...

Страница 16: ...usting screw Indicator Scale plate Lead wire Body Air flow PRESSURE SWITCH WITH T SPACER IS10T 20 D to IS10T 60 D IS10M 20 1 D to IS10M 60 1 D Air flow PRESSURE SWITCH WITH L PIPING ADAPTER IS10L 20 D...

Страница 17: ...ating the adjustment screw and setting the indicator to the figure on the scale Set pressure increases by rotating the adjustment screw clockwise Use a screwdriver of a size suitable for the groove of...

Страница 18: ...ssure 2 The lead wire cover has gouges or cracks 1 The lead wire has repeatedly been subject to bending or tensile force 1 Overcurrent was applied to the switch 1 Excessive impact has been applied to...

Страница 19: ...ld source provide a shield plate between the pressure switch and the source 1 1 Decrease the impact or use a solid state auto switch 5 The contact protection box has not been used The operating condit...

Страница 20: ...D 28 77 6 60 1 42 31 85 6 64 1 53 39 93 6 68 1 71 47 96 6 69 6 71 62 106 6 74 6 90 Model IS10M 20 D IS10M 30 D IS10M 40 D IS10M 50 D IS10M 60 D A B C D 10 6 83 8 66 3 42 12 6 91 8 70 3 53 14 6 97 8 7...

Страница 21: ...4 3 8 31 85 6 64 1 53 1 4 3 8 1 2 39 93 6 68 1 71 1 4 3 8 1 2 3 4 47 96 6 69 6 71 3 8 1 2 3 4 62 106 6 74 6 90 Model IS10 20 D IS10 30 D IS10 40 D IS10 50 D IS10 60 D Port size A B C D 1 8 1 4 28 77...

Страница 22: ...D 21 Port size A B C D E F 1 8 1 4 3 8 24 77 8 60 3 42 24 1 4 3 8 1 2 27 85 8 64 3 53 30 1 4 3 8 1 2 3 4 30 93 8 68 3 71 36 3 4 36 1 46 3 4 39 46 1 1 4 1 1 2 42 63 9 5 106 8 74 8 90 31 96 8 69 8 71 8...

Страница 23: ...cover Oct 2021 4 14 1 Sotokanda Chiyoda ku Tokyo 101 0021 JAPAN Tel 81 3 5207 8249 Fax 81 3 5298 5362 URL https www smcworld com Note Specifications are subject to change without prior notice and any...

Отзывы: