  Safety Instructions

 

 

These safety instructions are intended to prevent hazardous situations and/or equipment damage.

 

These instructions indicate the level of potential hazard with the labels of “Caution,” “Warning” or “Danger.”

 

They  are  all  important  notes  for  safety  and  must  be  followed  in  addition  to  International  Standards 
(ISO/IEC)

*1)

 , and other safety regulations.

 

*1) ISO 4414: Pneumatic fluid power -- General rules relating to systems.

 

   

ISO 4413: Hydraulic fluid power -- General rules relating to systems.

 

   

IEC 60204-1: Safety of machinery -- Electrical equipment of machines .(Part 1: General requirements)

 

   

ISO 10218: Manipulating industrial robots -Safety.

                                                                                 

 

 

  etc.

 

     

 
 

Caution

 

Caution

 indicates a hazard with a low level of risk which, if not avoided, could result 

in minor or moderate injury.

 

 
 

Warning

 

Warning

 

indicates a hazard with a medium level of risk which, if not avoided, could 

result in death or serious injury.

 

 
 

Danger

 

Danger

 

indicates a hazard with a high level of risk which, if not avoided, will result 

in death or serious injury.

 

 

Warning

 

1. The compatibility of the product is the responsibility of the person who designs the equipment or 

decides its specifications.

 

Since  the  product  specified  here  is  used  under  various  operating  conditions,  its  compatibility  with  specific 
equipment must be decided by the person who designs the equipment or decides its specifications based on 
necessary analysis and test results.   
The expected performance and safety assurance of the equipment will be the responsibility of the person who 
has determined its compatibility with the product.   
This  person  should  also  continuously  review  all  specifications  of  the  product  referring  to  its  latest  catalog 
information, with a view to giving due consideration to any possibility of equipment failure when configuring the 
equipment.

 

2. Only personnel with appropriate training should operate machinery and equipment.

 

The product specified here may become unsafe if handled incorrectly.

 

The  assembly,  operation  and  maintenance  of  machines  or  equipment  including  our  products  must  be 
performed by an operator who is appropriately trained and experienced.

 

3. Do not service or attempt to remove product and machinery/equipment until safety is confirmed.

 

1.The inspection and maintenance of machinery/equipment should only be performed after measures to   

prevent falling or runaway of the driven objects have been confirmed.

 

2.When the product is to be removed, confirm that the safety measures as mentioned above are implemented 
    and the power from any appropriate source is cut, and read and understand the specific product precautions 
    of all relevant products carefully.

 

3. Before machinery/equipment is restarted, take measures to prevent unexpected operation and malfunction.

 

4. Contact SMC beforehand and take special consideration of safety measures if the product is to 

be used in any of the following conditions.

 

1. Conditions and environments outside of the given specifications, or use outdoors or in a place exposed to 
    direct sunlight.

 

2. Installation on equipment in conjunction with atomic energy, railways, air navigation, space, shipping, 

  vehicles, military, medical treatment, combustion and recreation, or equipment in contact with food and 
  beverages, emergency stop circuits, clutch and brake circuits in press applications, safety equipment or 
  other applications unsuitable for the standard specifications described in the product catalog.

 

3. An application which could have negative effects on people, property, or animals requiring special safety   

analysis.

 

4.Use  in  an  interlock  circuit,  which  requires  the  provision  of  double  interlock  for  possible  failure  by  using  a 

mechanical protective function, and periodical checks to confirm proper operation. 

 

 

-2- 

Содержание IS10E-20-D

Страница 1: ...tch with T Spacer Pressure Switch with L Piping Adapter Pressure Switch with Piping Adapter MODEL Series Product Number IS10M 20 30 40 50 60 1 6 L P Z D IS10T 20 30 40 50 60 F N 6 L P Z D IS10L 20 30...

Страница 2: ...3 Standard Specifications 8 9 4 Electric circuit 10 5 Relation between Pressure setting and operating pressure 10 6 How to Order 11 14 7 Structural Drawing 15 8 Type of scale 15 9 Pressure Setting Me...

Страница 3: ...failure when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectly The assembl...

Страница 4: ...the product 3 Prior to using SMC products please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products 2 Vacuum pads are excluded from this...

Страница 5: ...the product after carefully reading and understanding the operation manual 2 Do not drop or apply impact during transportation or installation It will cause damage to the product or operation failure...

Страница 6: ...ing moment other than the weight of the product itself External piping needs to be supported separately as it may cause breakage Non flexible piping like steel tube is susceptible to excessive moment...

Страница 7: ...ct protection box connect the lead wire indicating SWITCH on the contact protection box and the lead wire from the switch The lead length between the switch body and the contact protection box should...

Страница 8: ...pplied to this product and that electrical cables are disconnected before performing maintenance 6 After maintenance confirm that the product satisfies specific functions and no external leakage occur...

Страница 9: ...x operating current Switch Characteristics Hysteresis Air 5 to 60 o C with no freezing 1 0MPa 0 7MPa 0 1MPa to 0 4MPa 24VAC DC or less 50mA 48VAC DC or less 40mA 100VAC DC or less 20mA Equivalent to I...

Страница 10: ...ess 50mA 48VAC DC or less 40mA 100VAC DC or less 20mA Equivalent to IP40 Model Max operating pressure Hysteresis Switch Characteristics Max operating current IS10E 20 D IS10E 30 D IS10E 40 D IS10E 50...

Страница 11: ...ic circuit 5 Relation between Pressure setting and operating pressure 10 0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 1 0 2 0 3 0 4 0 5 0 6 Operating pressure MPa Set pressure scale MPa ON pressure OFF pressure Hy...

Страница 12: ...e selected alphabetically a to d Note 2 Set pressure range of 6 psi 0 2 to 0 6 MPa 30 to 90 psi Note 3 Smaller face to face type cannot be mounted on the spacer with the bracket at both ends Mount a s...

Страница 13: ...Nil 0 5 3 Z 5 Nil MPa P MPa psi dual scale Note 1 A semi standard product can be selected alphabetically a to c Note 2 Set pressure range of 6P is 0 2 to 0 6MPa 30 to 90psi 3 4 Semi standard a Set pre...

Страница 14: ...il MPa P MPa psi dual scale Nil R Note 1 A semi standard product can be selected alphabetically a to d Note 2 Set pressure range of 6P is 0 2 to 0 6MPa 30 to 90psi a Set pressure range b Lead wire len...

Страница 15: ...MPa P MPa psi dual scale Nil R Note 1 A semi standard product can be selected alphabetically a to d Note 2 Set pressure range of 6P is 0 2 to 0 6MPa 30 to 90psi a Set pressure range b Lead wire length...

Страница 16: ...usting screw Indicator Scale plate Lead wire Body Air flow PRESSURE SWITCH WITH T SPACER IS10T 20 D to IS10T 60 D IS10M 20 1 D to IS10M 60 1 D Air flow PRESSURE SWITCH WITH L PIPING ADAPTER IS10L 20 D...

Страница 17: ...ating the adjustment screw and setting the indicator to the figure on the scale Set pressure increases by rotating the adjustment screw clockwise Use a screwdriver of a size suitable for the groove of...

Страница 18: ...ssure 2 The lead wire cover has gouges or cracks 1 The lead wire has repeatedly been subject to bending or tensile force 1 Overcurrent was applied to the switch 1 Excessive impact has been applied to...

Страница 19: ...ld source provide a shield plate between the pressure switch and the source 1 1 Decrease the impact or use a solid state auto switch 5 The contact protection box has not been used The operating condit...

Страница 20: ...D 28 77 6 60 1 42 31 85 6 64 1 53 39 93 6 68 1 71 47 96 6 69 6 71 62 106 6 74 6 90 Model IS10M 20 D IS10M 30 D IS10M 40 D IS10M 50 D IS10M 60 D A B C D 10 6 83 8 66 3 42 12 6 91 8 70 3 53 14 6 97 8 7...

Страница 21: ...4 3 8 31 85 6 64 1 53 1 4 3 8 1 2 39 93 6 68 1 71 1 4 3 8 1 2 3 4 47 96 6 69 6 71 3 8 1 2 3 4 62 106 6 74 6 90 Model IS10 20 D IS10 30 D IS10 40 D IS10 50 D IS10 60 D Port size A B C D 1 8 1 4 28 77...

Страница 22: ...D 21 Port size A B C D E F 1 8 1 4 3 8 24 77 8 60 3 42 24 1 4 3 8 1 2 27 85 8 64 3 53 30 1 4 3 8 1 2 3 4 30 93 8 68 3 71 36 3 4 36 1 46 3 4 39 46 1 1 4 1 1 2 42 63 9 5 106 8 74 8 90 31 96 8 69 8 71 8...

Страница 23: ...cover Oct 2021 4 14 1 Sotokanda Chiyoda ku Tokyo 101 0021 JAPAN Tel 81 3 5207 8249 Fax 81 3 5298 5362 URL https www smcworld com Note Specifications are subject to change without prior notice and any...

Отзывы: