IDX-OM-V024
Chapter 7
Documents
7.2
Refrigerant and GWP value
IDFB60/70/80/90 Series
7-2
Note 4: These values are reference values under rated conditions and are not guaranteed. Do not use
these values for the thermal set values, etc.
Note 5: Products other than Option R are not equipped with an earth leakage breaker. Purchase an
appropriate earth leakage breaker separately. Use an earth leakage breaker with a leak current
sensitivity of 30mA.
Note 6: This is the value specified by IPCC4 AR4. The value specified by
“Class 1 Act on Rational Use and
Proper Management of Fluorocarbons JAPAN
.” is R410A GWP: 2090.
Note 7: The maximum operating pressure is 150psi (1.0MPa) as standard, but it is possible to achieve
232psi (1.6MPa) when selecting Option L or Option V.
Coefficient factors
Inlet air temperature
o
F
80
90
100
110
120
130
140
149
o
C
27
32
37.8
43
49
54
60
65
IDFB60 / IDFB70
1.33
1.21
1.00
0.78
0.61
0.48
0.38
0.28
IDFB80 / IDFB90
1.38
1.38
1.00
0.83
0.63
0.50
0.45
0.37
Inlet air pressure
psi
50
60
70
80
90
100
120
140
145~232
MPa
0.35
0.41
0.48
0.55
0.62
0.69
0.83
0.97
1.00~1.60
IDFB60 / IDFB70
0.71
0.77
0.82
0.87
0.93
1.00
1.09
1.20
1.22
IDFB80 / IDFB90
0.77
0.82
0.86
0.90
0.94
1.00
1.07
1.16
1.18
Ambient temperature
o
F
80
90
100
110
113
o
C
27
32
37.8
43
45
IDFB60 / IDFB70
1.16
1.11
1.00
0.78
0.71
IDFB80 / IDFB90
1.40
1.22
1.00
0.88
0.83
Calculation example: The air flow capacity when the dew point of IDFB60 is set
to 10
o
C under the following conditions
< Operating conditions:
Inlet air temp: 100
o
F, Inlet air pressure: 90psi, Ambient temp: 90
o
F
>
177 SCFM×1.00 ×0.93 × 1.11
=
183 SCFM
7.2 Refrigerant and GWP value
Refrigerant
Global Warming Potential (GWP)
Regulation (EU) No 517/2014
(Based on the IPCC AR4)
Revised Fluorocarbons Recovery
and Destruction Law
(Japanese law)
R410A
2,088
2,090
Note 1: This product is hermetically sealed and contains fluorinated greenhouse gases (HFC).
Содержание IDFB60-23-C
Страница 26: ...IDX OM V024 Chapter 5 Checks and Maintenance 5 2 Regular maintenance IDFB60 70 80 90 Series 5 4 ...
Страница 36: ...IDX OM V024 Chapter 7 Documents 7 5 Air Refrigerant Circuit IDFB60 70 80 90 Series 7 6 ...
Страница 38: ...IDX OM V024 Chapter 8 Option C 8 2 Precautions for installation and handling IDFB60 70 80 90 Series 8 2 ...
Страница 50: ......
Страница 51: ......