IDX-OM-V020
Chapter 4
Operation/ Shutdown
4.3
Stop
IDFA60/70/80/90 Series
4-2
4.3 Stop
1) Turn off the switch with lamp.
2) The lamp turns off and operation stops.
4.4 Cautions for re-start
Allow at least 3 minutes before restarting the product. If the product is restarted within 3 minutes after
being stopped, the protection circuit will be activated, and the dryer will not start.
When operation does not start, restart it referring to the Chapter 6 Troubleshooting.
4.5 Check points before restart
When starting operation, check the following points. Immediately stop operation if any abnormality
occurs. Turn off the switch with lamp and shut off the breaker of the power supply.
- There should be no leakage of compressed air.
- Compressed air pressure, temperature, flow rate and ambient temperature are within the
specifications of the product.
- Confirm that drain comes out of the drain tube.
- The evaporation thermometer is in the green area.
- Drain should not be exhausted from the compressed air outlet of the air dryer.
- There should be no abnormality with noise or vibration or odor from the product.
4.6 Cautions when the product is shut down for an
extended period of time
- When the product is not used for longer than 24 hours, turn off the operation switch or power supply for
safety and saving energy. It is recommended to discharge pressure from the compressed air piping.
- The residual drainage in the air dryer may splash over the outlet when the operation is re-started, so it
is recommended to install a filter on the outlet of the air dryer.
Содержание IDFA60-23-C
Страница 12: ......
Страница 28: ...IDX OM V020 Chapter 5 Checks and Maintenance 5 2 Regular maintenance IDFA60 70 80 90 Series 5 4...
Страница 38: ...IDX OM V020 Chapter 7 Documents 7 5 Air Refrigerant Circuit IDFA60 70 80 90 Series 7 6...
Страница 40: ...IDX OM V020 Chapter 8 Option C 8 2 Precautions for installation and handling IDFA60 70 80 90 Series 8 2...