IDX-OM-V020
Chapter
11
Option T
IDFA60/70/80/90 Series
11.4
Connect the power cable and signal cable
11-3
11.4 Connect the power cable and signal cable
Connect the power cable and signal cable according to the procedure below.
1) Remove the front panel.
2) Insert the power cable to the power cable entry and connect to the terminal block.
3) Insert the signal cable to the signal cable entry and connect to the terminal block.
M3.5
Screw tightening torque: 1.0 to 1.3N
・
m
M4.0
Screw tightening torque: 1.4 to 2.0N
・
m
Do not touch any equipment other than the terminal block during wiring.
4) Mount the front panel back.
※
Refer to the Chapter 3.2.5 Electrical wiring for power cable connection.
1 2 3
PE
N
L
6
5
4
7
Rubber grommet
Signal cable entry
Strain relief
Power supply cable entry
(to be connected to the user's equipment)
IDFA60-23-T, IDFA70-23-T
IDFA80-23-T, IDFA90-23-T
Screws for connecting terminal block:
M3.5
Crimp terminal width: 8.5mm or less
Screws for connecting terminal block:
M4.0
Crimp terminal width: 9.5mm or less
Signal cable terminal
Front panel