IDX-OM-V020
Chapter
5
Checks and Maintenance
IDFA60/70/80/90 Series
5.2
Regular maintenance
5-3
7) Pull down the lock button of the bowl assembly with your thumb, and rotate the bowl assembly anticlockwise by
30 degrees to align the marks.
8) Remove the bowl assembly by pulling down on it.
(2) Mounting of the bowl assembly
1) Check that there are no scratches, twisting or adhesion of foreign matter on the bowl O-ring, then
thinly apply grease and mount it to the groove of the bowl assembly.
(The grease used recommends Krytox GPL 207 of Du Pont.)
2) Return the cleaned element to the bowl assembly.
3) Mount the bowl assembly to the body of the auto drain. Rotate it until the lock button stops
completely with a click. (Rotate the bowl assembly in the left and right direction lightly to ensure that
it will not rotate. If it rotates, re-do this step.)
4) Rotate the drain cock to the "S" side and mount a clip.
(Check that the drain cock will not rotate to the "O" side.)
5) Mount the drain tube as it was.
6) Open the ball valve.
Auto drain product number for replacement
Product No.
Product name
QTY.
AD52-A
Bowl assembly
1
KA00463
Bowl O-ring
1
AD402P-040S
Element
1
Turn
for
30
degrees.
(Both directions are
possible)
Bowl assembly
Bowl O-ring
Element
Bowl assembly
Lock
button
Align the mark and
pull the bowl
assembly down.
Mark
Mark
Содержание IDFA60-23-A
Страница 26: ...IDX OM V020 Chapter 5 Checks and Maintenance 5 2 Regular maintenance IDFA60 70 80 90 Series 5 4...
Страница 36: ...IDX OM V020 Chapter 7 Documents 7 5 Air Refrigerant Circuit IDFA60 70 80 90 Series 7 6...
Страница 40: ...IDX OM V020 Chapter 9 Option C 9 2 Precautions for installation and handling IDFA60 70 80 90 Series 9 2...
Страница 52: ......
Страница 53: ......