IDX-OM-V020
Chapter
8
Option A
IDFA60/70/80/90 Series
8.1
Safety instructions for use
8-1
Chapter 8 Option A
8.1 Safety instructions for use
Refer to the instructions below when handling the product.
WARNING
- Shut off the power supply when removing the panel for maintenance work, etc. The product
has a fan(s) and could cause serious danger to operators.
8.2 Specifications
Cool outlet air (10
o
C) can be supplied. The air flow with this option is smaller than that of the standard
dryer.
8.3 Air piping
Since cool air comes out from an outlet of air dryers, carefully attach thermal insulation to the piping at
air outlet and keep the piping length as short as possible in order to prevent condensation on the outlet
piping and temperature increase on the outlet due to ambient temperature.
8.4 Air flow capacity
Models
Item
IDFA60-23-A
IDFA70-23-A
IDFA80-23-A
IDFA90-23-A
Outlet air pressure dew point
o
C
10
Air flow capacity m
3
/h(ANR)
186
300
462
576
Outlet air temp.
o
C
10
Note1) The data for ANR is referring to the conditions of 20
o
C, 1atm. pressure & relative humidity of
65%.
Note2) The conditions are the same as the ones for standard models other than air flow capacity.
Содержание IDFA60-23-A
Страница 26: ...IDX OM V020 Chapter 5 Checks and Maintenance 5 2 Regular maintenance IDFA60 70 80 90 Series 5 4...
Страница 36: ...IDX OM V020 Chapter 7 Documents 7 5 Air Refrigerant Circuit IDFA60 70 80 90 Series 7 6...
Страница 40: ...IDX OM V020 Chapter 9 Option C 9 2 Precautions for installation and handling IDFA60 70 80 90 Series 9 2...
Страница 52: ......
Страница 53: ......