IDX-OM-W010
Air Dryer
13 Specification for Option S
13-1 Safety instructions
13- 1
IDF Series
13
Specification for Option S
13-1 Safety instructions
When handling the product, take care to the following precautions.
Warning
Only qualified persons are allowed to wire the product.
- Before wiring, be sure to shut off the power supply. Never perform wiring work while the
product is energized.
- Ensure a stable power supply with no voltage surges.
- Use a power supply suitable for the specifications of the product.
- Be sure to connect the ground connection.
- Grounding should never be connected to a water line, gas line or lightning rod.
- Multiple wiring is dangerous because it may lead to heat generation and cause a fire.
- Do not modify the electrical wiring of the power supply.
13-2 Specifications
The option allows the connection of a power cable to a terminal block.
IDF*-20 is equipped as standard.
.
IDF1E/2E/3E
For IDF1E~15E1-10
Terminal block cover
You can see the terminal block when you
remove this cover. Connect the power
cable through the membrane grommet.
L
N PE
( )
Rubber grommet
Power supply cable entry
To the user’s machine
Terminal connecting screw: M3
Crimped terminal width: 6.5mm or less
Applicable electric wire: 1.25mm2 or more