HRX-OM-K003
Chapter 3 Transporting and Installation
HRW Series
3.3 Procedure for Installation
3-9
M
a
i
F
r
3.3.4
Procedures for wiring installation
1.
Turn OFF the power breaker on customer side (primary side), and then use the assigned
procedures to peform lockout/tagout.
[Tips]
Connection of the power cable with this system must be established first.
Do not connect the cable with the factory side at this point.
2.
Turn OFF the main breaker of this system.
3.
Undo the screws (2 pcs.) to remove the front panel.
Be sure to use a Phillips screwdriver.
4.
Undo the screws (2 pcs.) to remove the breaker cover.
Be sure to use a Phillips screwdriver.
[Tips]
Make sure the breaker is at the ‘OFF’ position.
Otherwise, the removal of the front panel is not possible.
Be sure to turn OFF the factory side (primary side) power before
connection to this system.
Use the assigned procedure to peform lockout/tagout (Page 1-10).
Figure 3-6 Main Breaker OFF and Removal of Front Panel/Breaker Cover
Front
Front panel
Screw
Screw
OFF
Breaker cover
Breaker
Main breaker OFF
Содержание HRW002-H
Страница 6: ...HRX OM K003 Table of Contents HRW Series TOC 4...
Страница 22: ...HRX OM K003 Chapter 1 Safety 1 8 Material Safety Data Sheet MSDS HRW Series 1 16...
Страница 24: ...HRX OM K003 Chapter 2 Name of Each Section 2 1 Name of Each Section HRW Series 2 2...
Страница 38: ...HRX OM K003 Chapter 3 Transporting and Installation 3 3 Procedure for Installation HRW Series 3 14...
Страница 44: ...HRX OM K003 Chapter 4 System Startup and Shutdown 4 5 System Startup and Shutdown HRW Series 4 6...
Страница 60: ...HRX OM K003 Chapter 5 System Operation 5 4 Examples of System Operation HRW Series 5 16...
Страница 64: ...HRX OM K003 Chapter 6 Error Message and Troubleshooting 6 2 Troubleshooting HRW Series 6 4...
Страница 86: ......