background image

i

Limited Warranty

Limited Warranty Statement:

 SMC Networks, Inc. (“SMC”) warrants its products to be 

free from defects in workmanship and materials, under normal use and service, for the 
applicable warranty term. All SMC products carry a standard 90-day limited warranty from 
the date of purchase from SMC or its Authorized Reseller. SMC may, at its own discretion, 
repair or replace any product not operating as warranted with a similar or functionally 
equivalent product, during the applicable warranty term. SMC will endeavor to repair or 
replace any product returned under warranty within 30 days of receipt of the product. 

The standard limited warranty can be upgraded to a Limited Lifetime* warranty by 
registering new products within 30 days of purchase from SMC or its Authorized Reseller. 
Registration can be accomplished via the enclosed product registration card or online via 
the SMC Web site. Failure to register will not affect the standard limited warranty. The 
Limited Lifetime warranty covers a product during the Life of that Product, which is 
defined as the period of time during which the product is an “Active” SMC product. A 
product is considered to be “Active” while it is listed on the current SMC price list. As new 
technologies emerge, older technologies become obsolete and SMC will, at its discretion, 
replace an older product in its product line with one that incorporates these newer 
technologies. At that point, the obsolete product is discontinued and is no longer an 
“Active” SMC product. A list of discontinued products with their respective dates of 
discontinuance can be found at:

http://www.smc.com/index.cfm?action=customer_service_warranty

.

All products that are replaced become the property of SMC. Replacement products may 
be either new or reconditioned. Any replaced or repaired product carries either a 30-day 
limited warranty or the remainder of the initial warranty, whichever is longer. SMC is not 
responsible for any custom software or firmware, configuration information, or memory 
data of Customer contained in, stored on, or integrated with any products returned to 
SMC pursuant to any warranty. Products returned to SMC should have any 
customer-installed accessory or add-on components, such as expansion modules, 
removed prior to returning the product for replacement. SMC is not responsible for these 
items if they are returned with the product.

Customers must contact SMC for a Return Material Authorization number prior to 
returning any product to SMC. Proof of purchase may be required. Any product returned 
to SMC without a valid Return Material Authorization (RMA) number clearly marked on 
the outside of the package will be returned to customer at customer’s expense. For 
warranty claims within North America, please call our toll-free customer support number 
at (800) 762-4968. Customers are responsible for all shipping charges from their facility to 
SMC. SMC is responsible for return shipping charges from SMC to customer.

WARRANTIES EXCLUSIVE:

 IF AN SMC PRODUCT DOES NOT OPERATE AS 

WARRANTED ABOVE, CUSTOMER’S SOLE REMEDY SHALL BE REPAIR OR 
REPLACEMENT OF THE PRODUCT IN QUESTION, AT SMC’S OPTION. THE 
FOREGOING WARRANTIES AND REMEDIES ARE EXCLUSIVE AND ARE IN LIEU OF 
ALL OTHER WARRANTIES OR CONDITIONS, EXPRESS OR IMPLIED, EITHER IN 
FACT OR BY OPERATION OF LAW, STATUTORY OR OTHERWISE, INCLUDING 
WARRANTIES OR CONDITIONS OF MERCHANTABILITY AND FITNESS FOR A 
PARTICULAR PURPOSE. SMC NEITHER ASSUMES NOR AUTHORIZES ANY OTHER 
PERSON TO ASSUME FOR IT ANY OTHER LIABILITY IN CONNECTION WITH THE 
SALE, INSTALLATION, MAINTENANCE OR USE OF ITS PRODUCTS. SMC SHALL 

Содержание GS8P-SMART

Страница 1: ...MANAGEMENT GUIDE EZ SwitchTM 10 100 1000 8 Port Web Smart Switch with PoE SMCGS8P Smart...

Страница 2: ......

Страница 3: ...20 Mason Irvine CA 92618 Phone 949 679 8000 EZ Switch 10 100 1000 Installation Guide From SMC s EZ line of feature rich workgroup LAN solutions July 2007 Pub 150000022900H E072007 DT R02...

Страница 4: ...ed by implication or otherwise under any patent or patent rights of SMC SMC reserves the right to change specifications at any time without notice Copyright 2007 by SMC Networks Inc 20 Mason Irvine CA...

Страница 5: ...ecome the property of SMC Replacement products may be either new or reconditioned Any replaced or repaired product carries either a 30 day limited warranty or the remainder of the initial warranty whi...

Страница 6: ...N WITH THE SALE INSTALLATION MAINTENANCE USE PERFORMANCE FAILURE OR INTERRUPTION OF ITS PRODUCTS EVEN IF SMC OR ITS AUTHORIZED RESELLER HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES SOME STATES...

Страница 7: ...5 Displaying Status Overview 3 5 Showing Port Statistics 3 8 Displaying the System Name 3 10 Setting the Switch s IP Address 3 11 Configuring the Logon Password 3 12 Tools 3 12 Register Product 3 15 S...

Страница 8: ...dix A Software Specifications A 1 Software Features A 1 Management Features A 2 Standards A 2 Management Information Bases A 2 Appendix B Troubleshooting C 1 Forgot or Lost Password C 1 Changing a PC...

Страница 9: ...v Tables Tables Table 3 1 Web Page Configuration Buttons 3 2 Table 3 2 Switch Main Menu 3 3 Table 3 3 Port Statistics 3 8...

Страница 10: ...vi Tables...

Страница 11: ...Figure 3 11 Restart Switch 3 14 Figure 3 12 Register Product 3 15 Figure 3 13 Port Configuration 3 16 Figure 3 14 Port Broadcast Control 3 17 Figure 3 15 Port Mirroring 3 18 Figure 3 16 Cable Diagnos...

Страница 12: ...Figures viii...

Страница 13: ...l This protocol uses the Extensible Authentication Protocol over LANs EAPOL to request user credentials from the 802 1X client and then verifies the client s right to access the network via an authent...

Страница 14: ...ection of network nodes that share the same collision domain regardless of their physical location or connection point in the network The switch supports tagged VLANs based on the IEEE 802 1Q standard...

Страница 15: ...same subnet if they both have addresses that start 192 168 2 x If the PC and switch are not on the same subnet you must manually set the PC s IP address to 192 168 2 x where x is any number from 1 to...

Страница 16: ...Initial Configuration 2 2...

Страница 17: ...interface is controlled by the password See Configuring the Logon Password on page 3 12 Note If you cannot remember the switch s IP address you can restore the original settings by following the proc...

Страница 18: ...eb page configuration buttons Note To ensure proper screen refresh be sure that Internet Explorer is configured as follows Under the menu Tools Internet Options General Temporary Internet Files Settin...

Страница 19: ...basic system description including system name IP address port trunk and VLAN information 5 Statistics Shows statistics for port and interface 8 SYSTEM 10 Name Shows the name of the switch 10 LAN Sett...

Страница 20: ...n Control Protocol LACP on the switch 3 21 LACP Status Shows the LACP groups status 3 22 VLANS 21 VLAN Membership Configure VLAN port groups 3 23 VLAN Port Config Configures VLAN behavior for individu...

Страница 21: ...Note that the management station must always be on VLAN 1 Valid IP addresses consist of four decimal numbers 0 to 255 separated by periods Subnet Mask This mask identifies the host address bits used f...

Страница 22: ...nk labels Type All trunks and ports on this switch are 10 100 1000Mbps Trunk Status Indicates the speed and duplex setting of the trunk This can be changed on the TRUNKS Settings page 10hdx 10 Mbps ha...

Страница 23: ...Web Configuration 3 7 Web Click STATUS Overview Figure 3 3 Switch Information...

Страница 24: ...el protocols requested be transmitted and which were addressed to a broadcast address at this sub layer including those that were discarded or not sent Received High Priority Packets The total number...

Страница 25: ...ilization Broadcast Frames The total number of good frames received that were directed to the broadcast address Note that this does not include multicast packets CRC Alignment Errors The number of CRC...

Страница 26: ...S Statistics Figure 3 4 Port Statistics Displaying the System Name You can easily identify the system by displaying the device name Field Attributes Switch Name A name assigned to the switch system We...

Страница 27: ...of the VLAN interface that is allowed management access Valid IP addresses consist of four numbers 0 to 255 separated by periods Default 192 168 2 10 Subnet Mask This mask identifies the host address...

Страница 28: ...rocedure described in the Troubleshooting on page 1 37 Web Click System Password To change the password for the administrator enter current password the new password confirm it by entering it again th...

Страница 29: ...ided by SMC Select Upgrade Firmware from the Tools drop down list then click on the Browse button to select the firmware file Click the APPLY button to upgrade the selected switch firmware file You ca...

Страница 30: ...from the Tools drop down list then click Upload or Download and then click on the Browse button to select the file Figure 3 10 Upload Download Configuration Restart Switch Web Click SYSTEM Tools Rest...

Страница 31: ...ed time period You can also manually configure static MAC addresses that are assigned to specific ports on the switch A static MAC address is bound to a specific port and will not be moved or aged out...

Страница 32: ...t storms by setting a threshold for broadcast traffic for each port Any broadcast packets exceeding the specified threshold will then be dropped Field Attributes Type List the type of traffic which ca...

Страница 33: ...o mirror from this section of the page A port will be mirrored when the Mirroring Enabled check box is checked Port to Mirror to The port that will duplicate or mirror the traffic on the source port O...

Страница 34: ...rts to diagnose any cable faults short open etc and feedback a distance to the fault Field Attributes Cable Diagnostics Cable diagnostics is performed on a per port basis Select the port number from t...

Страница 35: ...ontains five radio buttons which are used to indicate which trunk if any the port belongs to Field Attributes Port The front panel port number Not a Trunk Member If the radio button in this column is...

Страница 36: ...guration Field Attributes Trunk Indicates trunk identification Speed Duplex Allows you to manually set the port speed and duplex mode for all ports in the trunk Flow Control Allows flow control to be...

Страница 37: ...which ports belong to the trunk Web Click TRUNKS Settings Figure 3 19 Trunk Rate Limiting LACP Setup The switch supports both static trunking and dynamic Link Aggregation Control Protocol LACP LACP co...

Страница 38: ...Aggregation Shows the status of each port The LACP Aggregation table has one row for each LACP group Normal means no LACP group is active For active LACP groups a new row is created from which the st...

Страница 39: ...oup Web Click TRUNKS LACP Status Figure 3 21 LACP Status Overview VLAN Settings This page allows you to create and delete VLANs Virtual LANs and to change the VLAN membership and behaviour of individu...

Страница 40: ...customer port should be set to VLAN unaware and a provider port trunk port should be set to VLAN aware Packet Type Sets the interface to accept all frame types including tagged or untagged frames or...

Страница 41: ...a server which means that authorized users can use the same credentials for authentication from any point within the network 802 1 X Setting The IEEE 802 1X standard defines a port based access contro...

Страница 42: ...d access Force Authorized Forces the port to grant access to all clients either 802 1X aware or otherwise Force Unauthorized Forces the port to deny access to all clients either 802 1X aware or otherw...

Страница 43: ...Attributes Port Statistics Statistics can be viewed on a per port basis Select the port that you want to view here Authenticator counters General statistics for authenticator Backend Authenticator co...

Страница 44: ...about themselves for the reasons of simplified troubleshooting enhanced network management and maintaining an accurate network topology LLDP capable devices periodically transmit information in messa...

Страница 45: ...e neighboring device Chassis ID The chassis information where the neighboring device is located Remote Port ID The remote port ID on the neighboring device System Name The neighboring devices full nam...

Страница 46: ...witch the management station must first submit a valid community string for authentication Field Attributes SNMP Enabled Activate or deactivate SNMP SNMP Trap Destination IP address of the trap manage...

Страница 47: ...s budget ports set at critical or high priority have power enabled in preference to those ports set at low priority For example when a device is connected to a port set to critical priority the switch...

Страница 48: ...Configuring the Switch 3 32 Web Click PoE Settings Figure 3 28 POE Configuration...

Страница 49: ...ol Full Duplex IEEE 802 3 2005 Half Duplex Back pressure Broadcast Storm Control Traffic throttled above a critical threshold Port Mirroring One source port one destination port Rate Limits Input Limi...

Страница 50: ...panning Tree Protocol IEEE 802 1p Priority tags IEEE 802 1Q VLAN IEEE 802 1X Port Authentication IEEE 802 3 2005 Ethernet Fast Ethernet Gigabit Ethernet Full duplex flow control Link Aggregation Contr...

Страница 51: ...XP PC 1 Click Start Control Panel then Network Connections 2 For the IP address you want to change right click the network connection icon and then click Properties 3 In the list of components used b...

Страница 52: ...the following IP address Then type your intended IP address Subnet mask and Default gateway in the provided text boxes 5 Click OK to save the changes Note For users of systems other than Windows 2000...

Страница 53: ......

Страница 54: ...echnischer Support und weitere Information unter www smc com SPANISH En www smc com Ud podr encontrar la informaci n relativa a servicios de soporte t cnico DUTCH Technische ondersteuningsinformatie b...

Отзывы: