5. Assembly, installation and piping 

1

)

 Assembly 

 

Assemble the product according to the following procedure. 

 

Check the contents 

Contents

 

   

Filter: 1 

   

Operation manual: 1 (This manual) 
Leg: 1 set 

   

Hexagon socket head bolt / Hexagon nut / Flat washer: (1 bag) 

   

Pressure gauges: 2 (for pressure gauge type) 

   

Take out the filter body. Mount the feet. 

 Refer to "1-1) Mounting of feet" on page 7. 

  ③

Install the pressure gauge (For pressure gauge type) 

 Refer to "1-2) Mounting of the pressure gauge"     

on page 7. 

1-1

)

 Mounting of feet 

*

Detachable feet are used for easy piping for discharging fluid.     

Piping will be easier if feet are removed before mounting for piping for discharging fluid. 

 

(

Piping for discharging fluid after mounting the feet limits the angle for rotating the mounting tool.

 )   

Mount the feet according to steps 

  and 

② 

below.   

<Accessory> Feet --- 1set (Hexagon socket head bolt / Hexagon nut / Flat washer: (1 bag) 

 

Mount the feet to the body (case). (Refer to Fig. 5-1, 5-2)

 

   

  Mount the feet so that they contact the hook of the case.   

For the insertion position, refer to the displayed position for mounting on the feet.   

 

   

Close the feet. Mount the hexagon socket head bolt / hexagon nut / flat washer to the mounting hole for the bolt of the feet.   

    (Fig. 5-3)    Tighten the bolts until the feet are fixed to the case so that they do not become loose.   

 
 
 
 
 
 
 
 
 
 
 
 
 
 

   

Be careful not to drop or knock over the body (case). 

 

1-2

Mounting the pressure gauges 

 

Mount the pressure gauges (2 pcs.) included in the package to the pressure ports (2 places) without 

    leakage.   

   

Note) Be careful not to tighten too much. Too much tightening can cause breakage.   

         

Use the seal tape for sealing. 

         

Recommended tightening torque: 12 to 14Nm. 

         

Mount the pressure gauges at an appropriate direction and angle so that the display is visible.   

 

  *Bag filter without the pressure gauge is shipped with plugs attached to the pressure gauge entry ports of the 

filter. It is possible to use it in this state.   

2) Installation 

   

Fix the feet to the ground using the foundation bolt (M16).     
When installing and piping, allow sufficient space for maintenance.   
Allow sufficient space for maintenance and inspection. 

Upper space of the product (Space for removal for replacing the element) --- 450mm or more

 

Around the band (Space for removal for replacing the element) --- 50mm or more around the band 

   

Reinforcement is necessary if the product is used in a location where it is exposed to vibration and   
impact.     

3) Piping 

   

Install a fluid discharge valve. It is necessary to discharge fluid from the reservoir for the replacement of   

Hook   

Case 

Leg 

Hexagon socket head bolt 
Hexagon nut 
Flat washer 

Mounting hole for bolt

 

Fig. 5-1. 

Fig. 5-2. 

Fig. 5-3. 

Discharge port 

Содержание FGFS1 Series

Страница 1: ...he model number of used bag filter Read and understand the Operation Manual before installing and operating the product In particular before restarting the product ensure that safety measures are take...

Страница 2: ...ications 6 1 How to order 6 2 Specifications 6 4 Circuit 6 5 Assembly Installation and piping 7 1 Assembly 7 1 1 Mounting of feet 1 2 Mounting of pressure sensor 2 Installation 7 3 Piping 8 6 Maintena...

Страница 3: ...ity with the product This person should also continuously review all specifications of the product referring to its latest catalog information with a view to giving due consideration to any possibilit...

Страница 4: ...cessary parts will be provided This limited warranty applies only to SMC product independently and not to any other damage incurred due to the failure of the product Prior to using SMC products please...

Страница 5: ...nt 450mm or more Around the band Space to remove the band for replacing the element 50mm or more for the upper space of the band This product is classed as a filter for liquid However the product may...

Страница 6: ...ce the element with a new one when the replacement timing has come Element replacement timing When pressure drop reaches 0 1 MPa Element replacement Maintenance should be performed according to the pr...

Страница 7: ...model number on the model number label for ordering parts Select the part number which is suitable for specified model number Note 2 is the space for the symbol of filtration Check the element part nu...

Страница 8: ...ant aqueous type oil based Alkalescent cleaning agent industrial water Not applicable for gas Fluids which corrode det eriorate or swell the filter and element material cannot be used Maximum operatin...

Страница 9: ...5 3 Tighten the bolts until the feet are fixed to the case so that they do not become loose Be careful not to drop or knock over the body case 1 2 Mounting the pressure gauges Mount the pressure gauge...

Страница 10: ...770 is the space for the symbol of filtration Check the element part number on the model number label before ordering e g Nominal filtration 5 m EJ501S 005 For the replacement of element Replace the e...

Страница 11: ...5 Caution Be careful not to burn your skin if the temperature is high 4 How to mount the element Pull the cloth handle of a new element to the center Squeeze the element brim to insert the element int...

Страница 12: ...ring Part number for replacement FGF KT01 FGFS1 Seal material NBR FGF KT02 FGFL1 Seal material FKM Replacement of O ring Replace O ring following steps 1 and 5 to 7 of P8 1 2 Element replacement proc...

Страница 13: ...RL http www smcworld com Note Specifications are subject to change without prior notice and any obligation on the part of the manufacturer 2020 SMC Corporation All Rights Reserved Revision history Rev...

Отзывы: