![SMC Networks FGFS1 Series Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/smc-networks/fgfs1-series/fgfs1-series_operation-manual_1301086009.webp)
9 / 13
FGX-OM-N027-B
5. Assembly, installation and piping
1
)
Assembly
Assemble the product according to the following procedure.
①
Check the contents
《
Contents
》
Filter: 1
Operation manual: 1 (This manual)
Leg: 1 set
Hexagon socket head bolt / Hexagon nut / Flat washer: (1 bag)
Pressure gauges: 2 (for pressure gauge type)
②
Take out the filter body. Mount the feet.
Refer to "1-1) Mounting of feet" on page 7.
③
Install the pressure gauge (For pressure gauge type)
Refer to "1-2) Mounting of the pressure gauge"
on page 7.
1-1
)
Mounting of feet
*
Detachable feet are used for easy piping for discharging fluid.
Piping will be easier if feet are removed before mounting for piping for discharging fluid.
(
Piping for discharging fluid after mounting the feet limits the angle for rotating the mounting tool.
)
Mount the feet according to steps
①
and
②
below.
<Accessory> Feet --- 1set (Hexagon socket head bolt / Hexagon nut / Flat washer: (1 bag)
①
Mount the feet to the body (case). (Refer to Fig. 5-1, 5-2)
Mount the feet so that they contact the hook of the case.
For the insertion position, refer to the displayed position for mounting on the feet.
②
Close the feet. Mount the hexagon socket head bolt / hexagon nut / flat washer to the mounting hole for the bolt of the feet.
(Fig. 5-3) Tighten the bolts until the feet are fixed to the case so that they do not become loose.
Be careful not to drop or knock over the body (case).
1-2
)
Mounting the pressure gauges
Mount the pressure gauges (2 pcs.) included in the package to the pressure ports (2 places) without
leakage.
Note) Be careful not to tighten too much. Too much tightening can cause breakage.
Use the seal tape for sealing.
Recommended tightening torque: 12 to 14Nm.
Mount the pressure gauges at an appropriate direction and angle so that the display is visible.
*Bag filter without the pressure gauge is shipped with plugs attached to the pressure gauge entry ports of the
filter. It is possible to use it in this state.
2) Installation
Fix the feet to the ground using the foundation bolt (M16).
When installing and piping, allow sufficient space for maintenance.
Allow sufficient space for maintenance and inspection.
Upper space of the product (Space for removal for replacing the element) --- 450mm or more
Around the band (Space for removal for replacing the element) --- 50mm or more around the band
Reinforcement is necessary if the product is used in a location where it is exposed to vibration and
impact.
3) Piping
Install a fluid discharge valve. It is necessary to discharge fluid from the reservoir for the replacement of
Hook
Case
Leg
Hexagon socket head bolt
Hexagon nut
Flat washer
Mounting hole for bolt
Fig. 5-1.
Fig. 5-2.
Fig. 5-3.
Discharge port