![SMC Networks FGFS1 Series Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/smc-networks/fgfs1-series/fgfs1-series_operation-manual_1301086007.webp)
7 / 13
FGX-OM-N027-B
2 Name and function of parts
1
)
Name and function of parts
Fig. 2-1 Name and function of parts
2-1. Name and function of parts
No.
Name of
components
Part no.
Application
type
Note 1)
Material
Function
1
Case
-
FGF
□
1
□
Stainless steel
Body
2
Cover
-
FGF
□
1
□
Stainless steel
The lid of the body
3
Band
FGF-BA01
FGF
□
1
□
Stainless steel
Attach the cover to the case and fix them.
4
O-ring
FGF-KT01
FGFS1
□
NBR
“O” ring which seals by the sealing part of the
cover and the case.
FGF-KT02
FGFL1
□
FKM
5
Basket
FGF-BT01
FGF
□
1A
Stainless steel
Basket for mounting the element and set to
the body.
FGF-BT02
FGF
□
1B
6
Holder Assembly
FGF-KT03
FGFS1
□
Polypropylene /
NBR
Seals the basket and the body
(O ring is attached to the holder)
FGF-KT04
FGFL1
□
Polypropylene /
FKM
7
Leg Assy
FGF-OP01
FGF
□
1
□
Carbon steel
Supports the body
8
Element
EJ501S-
※
Note2)
FGF
□
1A
Polyester
Filters the fluid
(Bag element made from non-woven cloth)
EJ601S-
※
Note2)
FGF
□
1B
Note 1) Check the model number on the model number label for ordering parts. Select the part number which is suitable for
specified model number.
Note 2)
※
is the space for the symbol of filtration.
Check the element part number on the model number label before ordering.
(Example) Nominal filtration rating 5um: EJ501S-005
Port to discharge all fluid in the case
during the replacement of the element.
(Port size : Rc2)
The outlet of filtered fluid.
(Port size : Rc2)
Clogging of element (pressure
drop) can be controlled by
checking the pressure on both
sides.
* For pressure gauge type,
use the pressure gauge for
monitoring
the
clogging
condition.
Displays the Inlet pressure
Displays the Outlet pressure
Feet are removable (Feet are not
mounted when purchased)
Piping will be easier if feet are
removed before mounting for piping
for discharging fluid.
Leg(Removable)
V band seat (At the front and the back)
The seat on which V band is placed for easy
mounting.
* Refer “Mounting of feet” on page
7 ”5.1-1” for mounting feet.
The inlet of filtered fluid.
(Port size: Rc2)
Rc1/4
Air release valve
Valve to discharge air left in the vessel
when the pump is pressurized for
starting.
(Port size: R1/4)