LED
■Remote e-CON type LED indicator
Input unit
Remote e-CON input type LED indicator
- Remote e-CON input type LED indicator specifications
LED name
Function
Color of
LED
Single Operation
PWR
Status of power supply voltage for
control
Green LED
is ON.
Normal power supply voltage for control and
input (US1) ON
OFF
Power supply for control and input (US1) is not
supplied.
10ms
Status of remote input
Green LED
is ON.
Operating normally
Red LED
flashes.
Restorable error is detected.
Short-circuit detection of power supply for
control / input
Red LED
flashes.
Abnormal power supply voltage for control and
input (US1)
(Applicable when the power supply voltage
monitor is enabled)
Red LED is
ON.
Unrecoverable error is detected.
OFF
Power supply for control and input (US1) is not
supplied.
W-SS
Radio wave receiving intensity
Green LED
is ON.
Received radio wave intensity level 3
Green LED
flashes
(1 Hz)
Received radio wave intensity level 2
NS: Green
LED
flashes
(2Hz)
Received radio wave intensity level 1
Red LED
flashes.
Wireless communication is not connected.
OFF
Not registered
W-NS
Wireless communication connection
status
Green LED
is ON.
Remote input (RY)
Red LED
flashes.
Remote input not connected
Red LED is
ON.
Remote input not connected
(Non-restorable error in wireless
communication)
Red/green Wireless communication connection is under
construction.
Orange
LED
flashes.
Pairing operation is in progress
OFF
Base not connected
* If there are multiple conditions for LED ON/Flashing, the detailed information can be seen only when the setting of the diagnostic
information is "Simple" or "Detailed".
Содержание EX600-WD Series
Страница 26: ...information is Simple or Detailed...
Страница 42: ...Dimensions EX600 WD E1...