-11-
No.EX##-OMK0004-A
■
Position of end plate
•
Be sure to connect the end plate (on the Input block side) at the left end of the manifold.
•
When the valve is not connected, be sure to connect the end plate R (on the Output block side) at the right
end of the manifold.
○
Installation example: Dimensions with solenoid valves unconnected [Unit: mm]
∗
: The number of Input The number of Output The number of Power Blocks: m
L
1
2
3
4
5
6
7
8
9
10
L 114 135 156 177 198 219 240 261 282 303
[mm]
∗
: Each dimension shows the SI unit without solenoid valves connected and with the end plate R (on the Output block side) connected.
Standard settings of L dimensions are with 10 or less m blocks. Contact SMC sales for the setting with over 10 blocks mounted.
Refer to the specification for each dimension when the solenoid valves are connected.
Wiring (for power supply, communication, input and output) and piping are done on only one side.
On the side, make a space for wiring and piping.
m