-11-
No.EX
※※
-OME0004-E
EX250-IE2
(M12 connector, 5 pin, Socket)
EX250-IE3
(M8 connector, 3 pin, Socket)
For the Cable side connector/Cable, refer to page
22
.
Be sure to check the specifications of the input signal when wiring the sensor. It may cause the malfunction.
Mind the position of the mounting key when selecting the sensor.
NOTE
Mount a waterproof cap on each unused connector of Input block. Proper use of the waterproof cap can
achieve IP67 enclosure. (Tightening torque: 0.05 Nm for M8, 0.1N m for M12)
For the waterproof cap, refer to page
22
.
Correlation between input number and Input Block
The total number of Input and Output blocks can not exceed 10.
The maximum input point is 32.
The input number is 0, 1 ...31 from the SI unit side.