background image

Minimum Stroke for Auto Switch Mounting

CKG1, CLK2G

Number of

auto switches

ø

40 to 

ø

63

1 pc.

2 pcs. (Different sides)

2 pcs. (Same side)

n pcs.

15

30

75

(mm)

MDB

Number of

auto switches

ø

32 to 

ø

125

ø

32

ø

40, 

ø

50

ø

63, 

ø

80

ø

100

ø

125

2 pcs. (Different sides, Same side)

1 pc.

15

80

85

90

95

100

Support brackets

other than center trunnion

Center trunnion

(mm)

15 + 50

n = 2, 4, 6, 8 ···

(n-2)

2

80 + 50

n = 4, 8, 12, 16 ···

(n-4)

2

85 + 50

n = 4, 8, 12, 16 ···

(n-4)

2

90 + 50

n = 4, 8, 12, 16 ···

(n-4)

2

95 + 50

n = 4, 8, 12, 16 ···

(n-4)

2

100 + 50

n = 4, 8, 12, 16 ···

(n-4)

2

n pcs.

CDNA

CDQS, CDQ2, CDLQ, CKQG, CLKQG

MGP, MLGP, MGPS

Number of

auto switches

ø

40 to 

ø

100

ø

40 to 

ø

63

ø

80

ø

100

2 pcs. (Different sides, Same side)

1 pc.

15

85

95

100

Support brackets

other than center trunnion

Center trunnion

(mm)

15 + 50

n = 2, 4, 6, 8 ···

(n-2)

2

85 + 50

n = 4, 8, 12, 16 ···

(n-4)

2

95 + 50

n = 4, 8, 12, 16 ···

(n-4)

2

100 + 50

n = 4, 8, 12, 16 ···

(n-4)

2

Number of

auto switches

CDQS

ø

25

CDQ2

ø

32 to 

ø

100

CDLQ

ø

25 to 

ø

100

CKQG, CLKQG

ø

50

1 pc.

2 pcs.

15

15

(mm)

Number of

auto switches

MGP

ø

25 to 

ø

100

MGPS

ø

50, 

ø

80

MLGP

ø

25 to 

ø

100

1 pc.

2 pcs.

15

15

(mm)

n pcs.

CDA2

Number of

auto switches

ø

40 to 

ø

100

ø

40 to 

ø

100

2 pcs. (Different sides, Same side)

1 pc.

15

85

Support brackets

other than center trunnion

Center trunnion

(mm)

15 + 50

n = 2, 4, 6, 8 ···

(n-2)

2

85 + 50

n = 4, 8, 12, 16 ···

(n-4)

2

n pcs.

MDNB

Number of

auto switches

ø

32 to 

ø

100

2 pcs. (Different sides, Same side)

1 pc.

15

Support brackets

(No center trunnion)

(mm)

15 + 50

n = 2, 4, 6, 8 ···

(n-2)

2

Note)  When a shorter stroke than the 

minimum feasible stroke is 
required for cylinder/actuator 
with built-in magnet, the stroke 
conforms to the feasible 
cylinder/actuator stroke. 

CKG1, CLK2G/

Two switches mounted 
on different sides

CKG1, CLK2G/

Two switches mounted 
on the same side
(75 mm strokes or more)

Note)  The standard strokes of the CKG1 and CLK2G are 

50, 75, 100, 125 and 150 mm. When two auto 
switches are mounted onto a cylinder with stroke 
50 mm, mount the auto switches on different sides. 

5

Series 

D-P3DW

 

D-P3DW-A.qxd  08.9.19 2:36 PM  Page 8

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Содержание D-P3DW* Series

Страница 1: ...in an environment which generates a magnetic field disturbance AC magnetic field If the current of the AC welding machine is 16000 A or lower the switch can be used even if the distance between the welding conductor and the cylinder actuator or auto switch is 0 mm RoHS compliant Existing model D P4DW D P3DW New Volume is reduced by 70 compared to existing switches Magnetic Field Resistant 2 Color ...

Страница 2: ...connector M12 Improved maintenance ability As an auto switch mounting bracket is fixed on the cylinder actuator side the position does not need to be readjusted when the auto switch is replaced Welding current ampere Distance between welding gun and auto switch mm 60 50 40 30 20 10 0 10000 20000 30000 Image of welding current and safety zone Danger zone Safety zone Image of danger zone If the curr...

Страница 3: ...to Switch Example CKG1A40 100Y P3DWSC S n Nil 2 pcs 1 pc n pcs Number of auto switches Auto switch Nil None For auto switch model refer to How to Order When cylinders actuators are ordered with an auto switch the cylinder actuator auto switch and auto switch mounting bracket including screws are enclosed When the auto switch is ordered on its own the auto switch mounting bracket is not included In...

Страница 4: ...h indicator light D P3DWSC D P3DWSE Lead wire Oilproof heavy duty vinyl cable ø4 8 0 5 mm2 2 cores Impact resistance Switch 1000 m s2 Connector 300 m s2 Insulation resistance 50 MΩ or more at 500 VDC Mega between lead wire and case Withstand voltage 1000 VAC for 1 minute between lead wire and case Ambient temperature 10 to 60 C Enclosure IEC60529 standard IP67 Polarity Non polar Magnetic Field Res...

Страница 5: ...an be used even if the distance between the welding conductor gun cable and the cylinder actuator or auto switch is 0 mm Please contact SMC when the AC welding current exceeds 16000 A OUT Brown OUT Blue Unit g Mass Auto switch model Lead wire length m 0 5 3 5 20 102 168 D P3DW L Z Dimensions Body Auto switch mounting bracket For round groove mounting BQ3 032S Auto switch mounting bracket For squar...

Страница 6: ...100 Hs Auto Switch Proper Mounting Position and Its Mounting Height CKG1 CLK2G MDB MDNB CDA2 CDNA CDQS CDQ2 CDLQ MGP MLGP MGPS CKQG CLKQG 3 Series D P3DW S20 201A D P3DW qxd 10 1 28 10 59 AM Page 4 Courtesy of Steven Engineering Inc 230 Ryan Way South San Francisco CA 94080 6370 Main Office 650 588 9200 Outside Local Area 800 258 9200 www stevenengineering com ...

Страница 7: ...12 17 5 32 34 5 38 44 47 5 57 5 67 5 mm MGP MLGP Bore size mm A B Hs 25 32 40 50 63 80 100 1 5 2 5 6 5 4 5 7 10 14 5 5 4 6 5 8 5 11 15 5 20 5 30 33 37 42 5 49 5 48 58 Ht 78 5 90 mm MGPS Bore size mm A B Hs 50 80 4 9 5 8 13 5 42 5 48 Ht 78 5 mm CKQG Bore size mm A B Hs 50 5 18 44 mm CLKQG Bore size mm A B Hs 50 40 50 44 mm CDQS Bore size mm A B Hs 25 1 5 0 0 32 mm Note The mounting position should ...

Страница 8: ... ø25 to ø100 MGPS ø50 ø80 MLGP ø25 to ø100 1 pc 2 pcs 15 15 mm n pcs CDA2 Number of auto switches ø40 to ø100 ø40 to ø100 2 pcs Different sides Same side 1 pc 15 85 Support brackets other than center trunnion Center trunnion mm 15 50 n 2 4 6 8 n 2 2 85 50 n 4 8 12 16 n 4 2 n pcs MDNB Number of auto switches ø32 to ø100 2 pcs Different sides Same side 1 pc 15 Support brackets No center trunnion mm ...

Страница 9: ... size mm mm Note Since this is a guideline including hysteresis not meant to be guaranteed Assuming approximately 30 dispersion Value may greatly change depending on the surrounding environment 6 Series D P3DW Magnetic Field Resistant 2 Color Display Solid State Auto Switch D P3DW A qxd 08 9 19 2 36 PM Page 9 Courtesy of Steven Engineering Inc 230 Ryan Way South San Francisco CA 94080 6370 Main Of...

Страница 10: ...ch mounting bracket temporarily by tightening the hexagon socket head cap screw M2 5 x 9 L 1 to 2 turns w Insert the temporarily tightened mounting bracket into the mat ing groove of the cylinder actuator and slide the auto switch onto the cyinder actuator through the groove e Check the detecting position of the auto switch and fix the auto switch firmly with the hexagon socket head cap screw M2 5...

Страница 11: ...e keeping firm contact between the bottom of the auto switch mounting bracket 2 and the cylinder tube w Insert the protrusion on the bottom of the auto switch into the mat ing part of the auto switch mounting bracket 1 and fix the auto switch and the auto switch mounting bracket 1 temporarily by tight ening the hexagon socket head cap screw M2 5 x 9 L 1 to 2 turns e Insert the temporarily tightene...

Страница 12: ...ipment including our products must be performed by an operator who is appropriately trained and experienced 3 Do not service or attempt to remove product and machinery equipment until safety is confirmed 1 The inspection and maintenance of machinery equipment should only be performed after measures to prevent falling or runaway of the driven objects have been confirmed 2 When the product is to be ...

Страница 13: ...iod which is clearly our responsibility a replacement product or necessary parts will be provided This limited warranty applies only to our product independently and not to any other damage incurred due to the failure of the product 3 Prior to using SMC products please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products 3 Vacuum pads ar...

Страница 14: ...el 5 Ensure sufficient clearance for maintenance activities When designing an application be certain to allow sufficient clearance for maintenance Caution 1 Confirm proper insulation of wiring Be certain that there is no faulty wiring insulation contact with other circuits ground fault improper insulation between termi nals etc Damage may occur due to excess current flow into a switch 2 Do not wir...

Страница 15: ...o switch s inter nal circuit elements Avoid sources of surge generation and disorganized lines 6 Avoid accumulation of iron waste or close contact with magnetic substances When a large amount of iron waste such as machining chips or spatter is accumulated or a magnetic substance some thing attracted by a magnet is brought into close proximity with a cylinder actuator with auto switches it may caus...

Страница 16: ...SOUTH KOREA SMC Pneumatics Korea Co Ltd TAIWAN SMC Pneumatics Taiwan Co Ltd THAILAND SMC Thailand Ltd NORTH AMERICA CANADA SMC Pneumatics Canada Ltd MEXICO SMC Corporation Mexico S A de C V U S A SMC Corporation of America SOUTH AMERICA ARGENTINA SMC Argentina S A BOLIVIA SMC Pneumatics Bolivia S r l BRAZIL SMC Pneumáticos do Brasil Ltda CHILE SMC Pneumatics Chile S A VENEZUELA SMC Neumatica Venez...

Отзывы: