Operating Environment

1. Never use in an atmosphere of explosive 

gases.

The structure of magnetic field resistant 2-color display solid 
state auto switches is not intended to prevent explosion. Nev-
er use in an atmosphere with an explosive gas since this may 
cause a serious explosion, and therefore, should absolutely 
not be used under these conditions.

Warning

1. Do not use around direct current welders.  

Magnetic field resistant 2-color display solid state auto 
switches will malfunction or magnets inside cylinders/actua-
tors will become demagnetized.

2. Do not use in an environment where the auto 

switch will be continually exposed to water.

Although the sensor unit of magnetic field resistant 2-color dis-
play solid state auto switches satisfies IEC standard IP67 con-
struction, do not use auto switches in applications where con-
tinually exposed to water splash or spray. Poor insulation or 
swelling of the potting resin inside auto switches may cause 
malfunction.

3. Do not use in an environment with oil or 

chemicals.

Please consult with SMC if auto switches will be used in an 
environment with coolant, cleaning solvent, various oils or 
chemicals. If magnetic field resistant 2-color display solid state 
auto switches are used under these conditions for even a 
short time, they may be adversely affected by improper insula-
tion, malfunction due to swelling of the potting resin, or hard-
ening of the lead wires.

4. Do not use in an environment with tempera-

ture cycles.

Please consult with SMC if magnetic field resistant 2-color dis-
play solid state auto switches are used where there are tem-
perature cycles other than normal temperature changes, as 
there may be adverse effects inside the auto switches.

5.  Do not use in an area where surges are gen-

erated.

When there are units (solenoid type lifter, high frequency in-
duction furnace, motor, etc.) which generate a large amount of 
surge in the area around cylinders/actuators with magnetic 
field resistant 2-color display solid state auto switches, this 
may cause deterioration or damage to the auto switch’s inter-
nal circuit elements. Avoid sources of surge generation and 
disorganized lines.

6.  Avoid accumulation of iron waste or close 

contact with magnetic substances.

When a large amount of iron waste such as machining chips 
or spatter is accumulated, or a magnetic substance (some-
thing attracted by a magnet) is brought into close proximity 
with a cylinder/actuator with auto switches, it may cause the 
magnetic field resistant 2-color display solid state auto switch 
to malfunction due to a loss of the magnetic force inside the 
cylinder/actuator.

Caution

1. Perform the following maintenance periodi-

cally in order to prevent possible danger 
due to unexpected magnetic field resistant 
2-color display solid state auto switch mal-
function.

1) Secure and tighten magnetic field resistant 2-color display 

solid state auto switch mounting screws.
If screws become loose or the mounting position is disloca-
ted, retighten them after readjusting the mounting position.

2) Confirm that there is no damage to lead wires.

To prevent faulty insulation, replace auto switches or repair 
lead wires, etc., if damage is discovered.

Maintenance

Caution

1. Leakage current is larger than the conven-

tional models.

When this auto switch is used to replace a conventional mod-
el, input devices sometimes cannot detect the OFF of the auto 
switch.

 

When OFF current of PLC is less than the auto switch 
leakage current 1 [mA]

Example) PLC that cannot use 2-wire type  

2. Please contact SMC for information about 

water resistance and flexibility of lead wires.

3. The resin case may discolor depending on 

the operating environment.

Although the resin case may be discolored by sunlight due to 
the characteristics of its material, it does not affect the 
strength and other characteristics.

Caution

Others

Magnetic Field Resistant 2-Color Display Solid State Auto Switch
Specific Product Precautions 2

Be sure to read this before handling. Refer to back pages 1 and 2 for Safety Instructions, 
“Handling Precautions for SMC Products” (M-E03-3) for Auto Switches Precautions.

Back page 4

D-P3DW-A.qxd  08.9.19 2:36 PM  Page 15

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Содержание D-P3DW* Series

Страница 1: ...in an environment which generates a magnetic field disturbance AC magnetic field If the current of the AC welding machine is 16000 A or lower the switch can be used even if the distance between the welding conductor and the cylinder actuator or auto switch is 0 mm RoHS compliant Existing model D P4DW D P3DW New Volume is reduced by 70 compared to existing switches Magnetic Field Resistant 2 Color ...

Страница 2: ...connector M12 Improved maintenance ability As an auto switch mounting bracket is fixed on the cylinder actuator side the position does not need to be readjusted when the auto switch is replaced Welding current ampere Distance between welding gun and auto switch mm 60 50 40 30 20 10 0 10000 20000 30000 Image of welding current and safety zone Danger zone Safety zone Image of danger zone If the curr...

Страница 3: ...to Switch Example CKG1A40 100Y P3DWSC S n Nil 2 pcs 1 pc n pcs Number of auto switches Auto switch Nil None For auto switch model refer to How to Order When cylinders actuators are ordered with an auto switch the cylinder actuator auto switch and auto switch mounting bracket including screws are enclosed When the auto switch is ordered on its own the auto switch mounting bracket is not included In...

Страница 4: ...h indicator light D P3DWSC D P3DWSE Lead wire Oilproof heavy duty vinyl cable ø4 8 0 5 mm2 2 cores Impact resistance Switch 1000 m s2 Connector 300 m s2 Insulation resistance 50 MΩ or more at 500 VDC Mega between lead wire and case Withstand voltage 1000 VAC for 1 minute between lead wire and case Ambient temperature 10 to 60 C Enclosure IEC60529 standard IP67 Polarity Non polar Magnetic Field Res...

Страница 5: ...an be used even if the distance between the welding conductor gun cable and the cylinder actuator or auto switch is 0 mm Please contact SMC when the AC welding current exceeds 16000 A OUT Brown OUT Blue Unit g Mass Auto switch model Lead wire length m 0 5 3 5 20 102 168 D P3DW L Z Dimensions Body Auto switch mounting bracket For round groove mounting BQ3 032S Auto switch mounting bracket For squar...

Страница 6: ...100 Hs Auto Switch Proper Mounting Position and Its Mounting Height CKG1 CLK2G MDB MDNB CDA2 CDNA CDQS CDQ2 CDLQ MGP MLGP MGPS CKQG CLKQG 3 Series D P3DW S20 201A D P3DW qxd 10 1 28 10 59 AM Page 4 Courtesy of Steven Engineering Inc 230 Ryan Way South San Francisco CA 94080 6370 Main Office 650 588 9200 Outside Local Area 800 258 9200 www stevenengineering com ...

Страница 7: ...12 17 5 32 34 5 38 44 47 5 57 5 67 5 mm MGP MLGP Bore size mm A B Hs 25 32 40 50 63 80 100 1 5 2 5 6 5 4 5 7 10 14 5 5 4 6 5 8 5 11 15 5 20 5 30 33 37 42 5 49 5 48 58 Ht 78 5 90 mm MGPS Bore size mm A B Hs 50 80 4 9 5 8 13 5 42 5 48 Ht 78 5 mm CKQG Bore size mm A B Hs 50 5 18 44 mm CLKQG Bore size mm A B Hs 50 40 50 44 mm CDQS Bore size mm A B Hs 25 1 5 0 0 32 mm Note The mounting position should ...

Страница 8: ... ø25 to ø100 MGPS ø50 ø80 MLGP ø25 to ø100 1 pc 2 pcs 15 15 mm n pcs CDA2 Number of auto switches ø40 to ø100 ø40 to ø100 2 pcs Different sides Same side 1 pc 15 85 Support brackets other than center trunnion Center trunnion mm 15 50 n 2 4 6 8 n 2 2 85 50 n 4 8 12 16 n 4 2 n pcs MDNB Number of auto switches ø32 to ø100 2 pcs Different sides Same side 1 pc 15 Support brackets No center trunnion mm ...

Страница 9: ... size mm mm Note Since this is a guideline including hysteresis not meant to be guaranteed Assuming approximately 30 dispersion Value may greatly change depending on the surrounding environment 6 Series D P3DW Magnetic Field Resistant 2 Color Display Solid State Auto Switch D P3DW A qxd 08 9 19 2 36 PM Page 9 Courtesy of Steven Engineering Inc 230 Ryan Way South San Francisco CA 94080 6370 Main Of...

Страница 10: ...ch mounting bracket temporarily by tightening the hexagon socket head cap screw M2 5 x 9 L 1 to 2 turns w Insert the temporarily tightened mounting bracket into the mat ing groove of the cylinder actuator and slide the auto switch onto the cyinder actuator through the groove e Check the detecting position of the auto switch and fix the auto switch firmly with the hexagon socket head cap screw M2 5...

Страница 11: ...e keeping firm contact between the bottom of the auto switch mounting bracket 2 and the cylinder tube w Insert the protrusion on the bottom of the auto switch into the mat ing part of the auto switch mounting bracket 1 and fix the auto switch and the auto switch mounting bracket 1 temporarily by tight ening the hexagon socket head cap screw M2 5 x 9 L 1 to 2 turns e Insert the temporarily tightene...

Страница 12: ...ipment including our products must be performed by an operator who is appropriately trained and experienced 3 Do not service or attempt to remove product and machinery equipment until safety is confirmed 1 The inspection and maintenance of machinery equipment should only be performed after measures to prevent falling or runaway of the driven objects have been confirmed 2 When the product is to be ...

Страница 13: ...iod which is clearly our responsibility a replacement product or necessary parts will be provided This limited warranty applies only to our product independently and not to any other damage incurred due to the failure of the product 3 Prior to using SMC products please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products 3 Vacuum pads ar...

Страница 14: ...el 5 Ensure sufficient clearance for maintenance activities When designing an application be certain to allow sufficient clearance for maintenance Caution 1 Confirm proper insulation of wiring Be certain that there is no faulty wiring insulation contact with other circuits ground fault improper insulation between termi nals etc Damage may occur due to excess current flow into a switch 2 Do not wir...

Страница 15: ...o switch s inter nal circuit elements Avoid sources of surge generation and disorganized lines 6 Avoid accumulation of iron waste or close contact with magnetic substances When a large amount of iron waste such as machining chips or spatter is accumulated or a magnetic substance some thing attracted by a magnet is brought into close proximity with a cylinder actuator with auto switches it may caus...

Страница 16: ...SOUTH KOREA SMC Pneumatics Korea Co Ltd TAIWAN SMC Pneumatics Taiwan Co Ltd THAILAND SMC Thailand Ltd NORTH AMERICA CANADA SMC Pneumatics Canada Ltd MEXICO SMC Corporation Mexico S A de C V U S A SMC Corporation of America SOUTH AMERICA ARGENTINA SMC Argentina S A BOLIVIA SMC Pneumatics Bolivia S r l BRAZIL SMC Pneumáticos do Brasil Ltda CHILE SMC Pneumatics Chile S A VENEZUELA SMC Neumatica Venez...

Отзывы: