How to Order of Pilot Valve Assembly
AV 2 0 - 1 G B A
Symbol
Description
Applicable size
AV
2000
AV
3000
AV
4000
AV
5000
❶
Body size
2
AV2000-A, AV3000-A
●
●
―
―
4
AV4000-A, AV5000-A
―
―
●
●
+
❷
a
d
Rated coil
voltage
AC
(50/60Hz)
1
AC100V
●
●
●
●
2
AC200V
●
●
●
●
3
AC110V [AC115V]
*1
●
●
●
●
4
AC220V [AC230V]
*1
●
●
●
●
DC
5
DC24V
●
●
●
●
6
DC12V
●
●
●
●
+
❸
e
Electrical entry
G
Grommet
(
Lead wire length: 300mm
)
●
●
●
●
D
Type D
(
DIN terminal/With connector
)
●
●
●
●
Y
Type Y
(
DIN terminal/With connector
)
*
2
●
●
●
●
DO
Type D
(
DIN terminal/Without connector
)
●
●
●
●
YO
Type Y
(
DIN terminal/Without connector
)
●
●
●
●
+
❹
f
Light/
surge voltage suppressor
NIL
None
●
●
●
●
Z
With light/surge voltage suppressor
〇
*3
〇
*3
〇
*3
〇
*3
+
❺
g
Manual override
NIL
Non-locking push type
●
●
●
●
B
Push-turn locking slotted type
●
●
●
●
C
Push-turn locking lever type
●
●
●
●
*1 The 110 VAC and 115 VAC are interchangeable. The 220 VAC and 230 VAC are interchangeable as well.
The allowable voltage fluctuation is -15% to +5% of the rated voltage for the 115 VAC or 230 VAC.
*2 Type “Y” is a DIN terminal conforming to EN-175301-803C
(
former DIN43650C
)
.
*3 When the electrical entry is DO or YO, light/surge voltage suppressor cannot be selected.
-20-
❷
❸
❹
❺
❶