C
ABLES
B-3
1000BASE-T Pin Assignments
1000BASE-T ports support automatic MDI/MDI-X operation, so
you can use straight-through cables for all network connections. In
straight-through cable, pins 1-8, at one end of the cable, are
connected straight through to pins 1-8 at the other end of the
cable.
Use 100-ohm Category 5 or 5e unshielded twisted-pair (UTP) or
shielded twisted-pair (STP) cable for 1000BASE-T connections.
Also be sure that the length of any twisted-pair connection does not
exceed 100 meters (328 feet).
The table below shows the 1000BASE-T MDI and MDI-X port
pinouts. These ports require that all four pairs of wires be
connected. Note that for 1000BASE-T operation, all four pairs of
wires are used for both transmit and receive.
Pin
MDI Signal Name
MDI-X Signal Name
1
Transmit Data plus (TD1+)
Transmit Data plus (TD2 +)
2
Receive Data minus (RD1-)
Receive Data minus (RD2-)
3
Transmit Data plus (TD2+)
Transmit Data plus (TD1+)
4
Transmit Data plus (TD3+)
Transmit Data plus (TD4+)
5
Receive Data minus (RD3-)
Receive Data minus (RD4-)
6
Receive Data minus (RD2-)
Receive Data minus (RD1-)
7
Transmit Data plus (TD4+)
Transmit Data plus (TD3+)
8
Receive Data minus (RD4-)
Receive Data minus (RD3-)
Содержание 9452TX
Страница 2: ......
Страница 10: ...COMPLIANCES vi ...
Страница 22: ...INSTALLING THE NETWORK CARD 1 10 ...
Страница 50: ...CABLES B 4 ...
Страница 54: ...SPECIFICATIONS C 4 ...
Страница 61: ......