ROUBLESHOOTING
Diagnosing Switch Indicators
Table A-1 Troubleshooting Chart
Symptom
Action
PWR LED is Off
• Check connections between the switch, the power cord and
the wall outlet.
• Contact your dealer for assistance.
PWR LED is Amber • Internal power supply has failed.
• Contact your local dealer for assistance.
Diag LED is Amber
• Power cycle the switch to try and clear the condition
• If the condition does not clear, contact your dealer for
assistance
Stack Master LED is
Flashing Amber
• The stack has not completed its initial configuration.
Wait a few minutes for the process to complete.
• If flashing continues, check that the Master Select
button is pressed in on only one switch.
• Check that all stacking cables are properly connected.
Link LED is Off
• Verify that the switch and attached device are powered on.
• Be sure the cable is plugged into both the switch and
corresponding device.
• If the switch is installed in a rack, check the connections to the
punch-down block and patch panel.
• Verify that the proper cable type is used and its length does not
exceed specified limits.
• Check the adapter on the attached device and cable
connections for possible defects. Replace the defective
adapter or cable if necessary.
Содержание 8724M INT
Страница 2: ......
Страница 14: ...COMPLIANCES x ...
Страница 20: ...FIGURES xvi ...
Страница 50: ...INSTALLING THE SWITCH 3 14 ...
Страница 62: ...TROUBLESHOOTING A 4 ...
Страница 72: ...SPECIFICATIONS C 4 Safety CSA CUS CSA 60950 UL60950 TÜV GS EN60950 1 CB IEC 60950 1 Warranty Limited Lifetime ...
Страница 74: ...ORDERING INFORMATION D 2 ...
Страница 80: ...Glossary 6 ...
Страница 84: ...INDEX Index 4 ...
Страница 85: ......