N
ETWORK
P
LANNING
2-6
Application Notes
1. Full-duplex operation only applies to point-to-point access (such as
when a switch is attached to a workstation, server or another switch).
When the switch is connected to a hub, both devices must operate in
half-duplex mode.
2. Avoid using flow control on a port connected to a hub unless it is
actually required to solve a problem. Otherwise back pressure jamming
signals may degrade overall performance for the segment attached to the
hub.
3. As a general rule the length of fiber optic cable for a single switched link
should not exceed:
•
1000BASE-SX: 550 m (1805 ft) for multimode fiber.
•
1000BASE-LX: 5 km (3.1 miles) for single-mode fiber.
•
1000BASE-ZX: 100 km (62.14 miles) for single-mode fiber.
However, power budget constraints must also be considered when
calculating the maximum cable length for your specific environment.
Содержание 8724M INT
Страница 2: ......
Страница 14: ...COMPLIANCES x ...
Страница 20: ...FIGURES xvi ...
Страница 50: ...INSTALLING THE SWITCH 3 14 ...
Страница 62: ...TROUBLESHOOTING A 4 ...
Страница 72: ...SPECIFICATIONS C 4 Safety CSA CUS CSA 60950 UL60950 TÜV GS EN60950 1 CB IEC 60950 1 Warranty Limited Lifetime ...
Страница 74: ...ORDERING INFORMATION D 2 ...
Страница 80: ...Glossary 6 ...
Страница 84: ...INDEX Index 4 ...
Страница 85: ......