C
ONFIGURING
THE
S
WITCH
3-108
The switch supports both static trunking and dynamic Link Aggregation
Control Protocol (LACP). Static trunks have to be manually configured at
both ends of the link, and the switches must comply with the Cisco
EtherChannel standard. On the other hand, LACP configured ports can
automatically negotiate a trunked link with LACP-configured ports on
another device. You can configure any number of ports on the switch as
LACP, as long as they are not already configured as part of a static trunk. If
ports on another device are also configured as LACP, the switch and the
other device will negotiate a trunk link between them. If an LACP trunk
consists of more than eight ports, all other ports will be placed in a standby
mode. Should one link in the trunk fail, one of the standby ports will
automatically be activated to replace it.
Command Usage
Besides balancing the load across each port in the trunk, the other ports
provide redundancy by taking over the load if a port in the trunk fails.
However, before making any physical connections between devices, use
the web interface or CLI to specify the trunk on the devices at both ends.
When using a port trunk, take note of the following points:
•
Finish configuring port trunks before you connect the corresponding
network cables between switches to avoid creating a loop.
•
You can create up to 32 trunks on the switch, with up to eight ports
per trunk. Note that because the stack functions conceptually as a
single system, you can include ports from different units in the same
stack. For example, you could connect ports spread across several units
that belong to VLAN 2 into a common trunk.
•
The ports at both ends of a connection must be configured as trunk
ports.
•
When configuring static trunks on switches of different types, they
must be compatible with the Cisco EtherChannel standard.
•
The ports at both ends of a trunk must be configured in an identical
manner, including communication mode (i.e., speed, duplex mode and
flow control), VLAN assignments, and CoS settings.
Содержание 8700S-130
Страница 2: ......
Страница 3: ......
Страница 8: ...LIMITED WARRANTY iv ...
Страница 56: ...INITIAL CONFIGURATION 2 18 ...
Страница 189: ...PORT CONFIGURATION 3 133 Figure 3 61 Port Statistics continued ...
Страница 566: ...COMMAND LINE INTERFACE 4 294 ...
Страница 571: ...SOFTWARE SPECIFICATIONS A 5 Trap RFC 1215 UDP MIB RFC 2012 ...
Страница 572: ...SOFTWARE SPECIFICATIONS A 6 ...
Страница 576: ...TROUBLESHOOTING B 4 ...
Страница 589: ......
Страница 591: ...38 Tesla Irvine CA 92618 Phone 949 679 8000 ...
Страница 592: ... 8 ...