U
SER
A
UTHENTICATION
3-61
Remote
Authentication
Dial-in User
Service (RADIUS)
and Terminal
Access Controller
Access Control
System Plus
() are
logon authentication protocols that use software running on a central
server to control access to RADIUS-aware or TACACS -aware devices on
the network. An authentication server contains a database of multiple user
name/password pairs with associated privilege levels for each user that
requires management access to the switch.
RADIUS uses UDP while uses TCP. UDP only offers best
effort delivery, while TCP offers a connection-oriented transport. Also,
note that RADIUS encrypts only the password in the access-request
packet from the client to the server, while encrypts the entire
body of the packet.
Command Usage
•
By default, management access is always checked against the
authentication database stored on the local switch. If a remote
authentication server is used, you must specify the authentication
sequence and the corresponding parameters for the remote
authentication protocol. Local and remote logon authentication
control management access via the console port, web browser, or
Telnet.
•
RADIUS and logon authentication assign a specific
privilege level for each user name/password pair. The user name,
password, and privilege level must be configured on the authentication
server.
Web
Telnet
RADIUS/
server
console
1. Client attempts management access.
2. Switch contacts authentication server.
3. Authentication server challenges client.
4. Client responds with proper password or key.
5. Authentication server approves access.
6. Switch grants management access.
Содержание 8700S-130
Страница 2: ......
Страница 3: ......
Страница 8: ...LIMITED WARRANTY iv ...
Страница 56: ...INITIAL CONFIGURATION 2 18 ...
Страница 189: ...PORT CONFIGURATION 3 133 Figure 3 61 Port Statistics continued ...
Страница 566: ...COMMAND LINE INTERFACE 4 294 ...
Страница 571: ...SOFTWARE SPECIFICATIONS A 5 Trap RFC 1215 UDP MIB RFC 2012 ...
Страница 572: ...SOFTWARE SPECIFICATIONS A 6 ...
Страница 576: ...TROUBLESHOOTING B 4 ...
Страница 589: ......
Страница 591: ...38 Tesla Irvine CA 92618 Phone 949 679 8000 ...
Страница 592: ... 8 ...