![SMC Networks 7724M/VSW - annexe 1 Скачать руководство пользователя страница 296](http://html1.mh-extra.com/html/smc-networks/7724m-vsw-annexe-1/7724m-vsw-annexe-1_manual_1299754296.webp)
Management Guide
CLI
TigerAccess™ EE
SMC7824M/VSW
295
8.4.4.4 Control
VLAN
RM Node periodically sends “RM Test Packet” message to detect the loop. RM Test
packet message can be transmiited by control VLAN only. Each ERP domain should have
one control VLAN.
To configure a control VLAN of an ERP domain, use the following command.
Command Mode
Description
control-vlan
VLAN
Configures a control VLAN of ERP domain.
no control-vlan
ERP
Domain
Deletes configured control VLAN of ERP domain
8.4.4.5
ERP Ring Priority
The Super Loop occurs because of a shared link’s failure between two ERP rings. A do-
main with higher priority (one of the RM nodes) is the only responsible for monitoring the
ports of a shared link. The control packets of a domain with lower ring priority can be
transmitted to another domain with higher priority to prevent the super loop.
It means that the higher ring priority domain guarantees the detour path against a shared
link of lower ring priority domain.
To specify ERP ring priority, use the following command.
Command Mode
Description
ring-priority
<1-255>
ERP
Domain
Specifies ERP ring priority
1-255: ERP ring priority value (default: 0)
To return ERP ring priority as default, use the following command.
Command Mode
Description
no ring-priority
ERP
Domain
Configures ERP ring priority as default value
8.4.4.6 Displaying
ERP
Domian
To display a configuration for specific ERP domain, use the following command.
Command Mode
Description
show pending
Shows modified configurations of ERP domain.
show current
Shows updated configuration of ERP domain.
show
ERP
Domain
Shows all of configuration of ERP domain.