![SMC Networks 7724M/VSW - annexe 1 Скачать руководство пользователя страница 239](http://html1.mh-extra.com/html/smc-networks/7724m-vsw-annexe-1/7724m-vsw-annexe-1_manual_1299754239.webp)
CLI
Management Guide
TigerAccess™ EE
238
SMC7824M/VSW
8.1.4 Subnet-based
VLAN
An IP address contains two parts: a subnet identifier and a station identifier. The switch
performs two operations to create IP subnet-based VLANs.
•
Parse the protocol type to determine if the frame encapsulates an IP datagram.
•
Examine and extract the IP subnet portion of the IP Source Address in the encapsu-
lated
datagram.
Once it is known that a given frame carries an IP datagram belonging to a given subnet,
the switch can transmit the frame as needed within the confines of the subnet to which it
belongs. If a device with a given IP address moves within the VLAN-aware network, the
boundaries of its IP subnet can automatically adjust to accommodate the station’s ad-
dress.
VLAN 1
IP Subnet 192.168.10.0
VLAN 2
IP Subnet 192.168.20.0
VLAN 3
IP Subnet 192.168.30.0
Fig. 8.2
Subnet-based VLAN
To configure subnet-based VLAN, use the following command.
Command Mode
Description
vlan subnet
A.B.C.D/M
VLANS
Bridge
Configures subnet based VLAN.
VLANS: VLAN ID (1-4094)
To clear subnet-based VLAN configuration, use the following command.
Command Mode
Description
no vlan subnet
[
A.B.C.D/M
]
Bridge
Clears configured VLAN based on subnet.
8.1.5 Tagged
VLAN
In a VLAN environment, a frame’s association with a given VLAN is soft; the fact that a
given frame exists on some physical cable does not imply its membership in any particu-
lar VLAN. VLAN association is determined by a set of rules applied to the frames by
VLAN-aware stations and/or switches.