Specifications:

Construction:                       5100-28 Sentry Display Bus

Dimensions:

13.5 x 4.75 x 4.2 inches 

(HxWxD)

(34.3 x 12.1 x 10.7 cm)

Weight:

5 lb. (2.2 Kg)

Housing:

Explosion proof,
Class 1, Div. I, Groups B, 
C, D

Appovals

CSA Class 1, DIN I, 
Groups B, C, D NRTL/C

Warranty:

2 years

(Specifications subject to change without notice)

Sensor type:

Infrared

Performance

Range:

0-100% LEL methane or 
propane (Other Hydrocarbons 
on request)

Repeatability:

+/-2% LEL

Linearity:

+/- 3% LEL

Zero Drift:

< 1% per month

Response time:

30 sec to 90% Full Scale

Accuracy:

 + 3% LEL up to 50% LEL,
 + 5% LEL above 50% LEL

Sensor Life:

Typically >5 years (for use at 
standard temperature & 
pressure)

Operating Range:

Ambient Temperature 
Range: 

-40o to 167oF (-40o to 75oC)

Relative Humidity:

5-99%

Electrical Data:

Power consumption:

3.0 watts nominal, 5.0 watts 
maximum

Loop type:

3 wire

Loop resistance:

800 Ohms @ 

Содержание 4101-28

Страница 1: ...vides instructions for the following Sierra Monitor products Model Description 4101 28 IR Gas Sensor Module 4 20 mA output 5100 28 IR Gas Sensor Module Sentry bus output The instructions are effective for the above models as of October 2002 Instruction Manual Part Number T12013 Rev B1 ...

Страница 2: ......

Страница 3: ...ounting 2 2 2 Wiring 4 20 mA version 2 2 2 1 Wiring 2 2 2 2 Jumper Location for Non Isolated Isolated Current Output 2 2 2 3 Initial LED Status 4 20mA Operator 2 2 2 4 Sensor Life 3 2 2 5 Test Jacks 3 2 3 Wiring and System Installation Model 5000 Application 5 2 3 1 Wiring 5 3 0 Calibration 6 3 1 Overview 6 3 2 Local Calibration Procedure 6 3 3 Start Calibration 6 4 0 Specifications 7 5 0 Limited ...

Страница 4: ...How It Works Most combustible gases absorb infrared light energy at defined wavelengths providing an absorption sig nature for that gas The principle of an infrared de tector is based upon the absorption of the infrared light at a specific wavelength as it passes through the gas The more of the absorbing gas that is present the more light is absorbed The detector measures the energy coming from an...

Страница 5: ...d cable See table be low Refer to applicable wiring codes when installing and wiring the 4101 28 After the field wiring has been carefully connected as per Fig 2 1 CHECK THAT THE CORRECT WIRES ARE CONNECTED TO THE CORRESPONDINGTERMINALSANDTHAT VOLTAGE LEVELS DO NOT EXCEED THE SPECIFICATIONS When the wiring and voltages have been verified gently plug in the control module Use gentle hand pressure t...

Страница 6: ...in across a broad range without any need for manual adjustment of potentiometers or jump ers 2 2 5 Test Jacks The module is equipped with test jacks to facilitate con venient current loop measurements without opening the external current loop To make measurements use the following procedure 1 Attach the current meter leads to the test jacks lo cated on the face plate 2 Apply test gas and take mete...

Страница 7: ...Instruction Manual Model 4101 28 5100 28 IR Gas Sensor Module 7 03 Page Figure 2 0 Wiring Connections Settings 4 ...

Страница 8: ...em Ver 6 0 In struction Manual 2 3 1 Wiring Caution To access the wiring connections on the 5100 28 you will need to remove the enclosure cover and then remove the cover plate To remove the cover plate pull gently using the knob in the center of the board 1 See Table 1 for wire gauge recommendations 2 Connect P 1 from Sentry channel to the terminal at the right hand side which is labelled 24VDC po...

Страница 9: ... LEL Methane balance air or 1256 28 Cylinder of 50 LEL Propane bal ance air 1256 04 2LPM flow Regulator 1255 02 Gas Calibration Tubing PTFE or equal 1 4 OD 1250 04 Calibration Kit is a case for storage of 2 cylinders and contains the tubing and regulator 3 3 Start Calibration 1 Deliver air if necessary for 2 minutes at 2LPM Remove at step noted below 2 Place and hold curved side of the magnet atta...

Страница 10: ...subject to change without notice Sensor type Infrared Performance Range 0 100 LEL methane or propane Other Hydrocarbons on request Repeatability 2 LEL Linearity 3 LEL Zero Drift 1 per month Response time 30 sec to 90 Full Scale Accuracy 3 LEL up to 50 LEL 5 LEL above 50 LEL Sensor Life Typically 5 years for use at standard temperature pressure Operating Range Ambient Temperature Range 40o to 167oF...

Страница 11: ...ich original identification marks have been removed or altered This Limited Warranty also will not apply to in terconnecting cables or wires consumables ie calibration gases batteries sensors nor to any damage resulting from battery leakage In all cases SMC s responsibility and liability under this war ranty shall be limited to the cost of the equipment The pur chaser must obtain shipping instruct...

Страница 12: ......

Отзывы: