Press and hold down the Scroll key now press and hold the Mute key. Hold together for 3 seconds. This will 
bring you to the Set-Up Menu.

 

 

 

 

 

 

 

 

 

Use the Scroll or Backlight key to scroll t

o “Calibrate” and press the ENTER Key. 

This will bring you to the Calibrate Menu. 
 

The display will now show

 

 

 

 

 

 

 

 

 

 
Use the Scroll key to scroll to switch between them, then press the Enter key. 
 
 
 

 

Two different methods of tank programming are available if using the pressure sensor: 

 

2 Point Calibration:

 sets tank low and high points which can only be used if the tank is a regular shape.  

 

5 Point Calibration: 

sets tank low, tank quarter, tank half, tank three quarters and tank full points, offering 

more accuracy if the tank is an irregular shape.  

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 Sensor Programming Instructions

 

 

SET-UP    MENU 

 

Program Tank         
Calibrate      
Set Alarm             
More          
 

Calibration 

 

 2 Point                                           
 5 Point             
 

Содержание TD-1000

Страница 1: ...TD 1000 Tank Monitor Installation Manual...

Страница 2: ...300Ma 12vdc Pump output 4 Amps 12vdc Size 65mm x 65mm x 80mm Deep Data Retention 50 years without power Outputs Pump Output 4 Amps 12vdc The TD 1000 has one output which can be used to control an int...

Страница 3: ...3 TD 1000 Wiring Red Battery Black Sensor Black Buzzer Blue Buzzer White Output Green Sensor In Black Battery Purple Sensor Connector Mounting 50mm Size 75mm x 75mm Drill a hole using a 50mm hole saw...

Страница 4: ...te Relay Toilet Disable Connection Toilet Pump Toilet Pump Blue wire Relay Toilet Disable Connected to SmartSwitch Toilet controller connect blue output wire to SmartSwitch STS 220 toilet controller a...

Страница 5: ...ush the Enter button to select the tank Name or scroll to another name PLEASE SEE PAGE 8 FOR SENSOR CALIBRATION Step 3 Setting the Alarm point The display will now show The alarm point is the point wh...

Страница 6: ...ed the pump output will turn on and automatically turn Off when the Pump Off point is reached If the tank name is either Black or Grey the pump will stop when the tank is equal to or less than the pro...

Страница 7: ...e adaptor is attached make sure that the hole in the adaptor is clear of any excess glue Allow drying as per the instructions for the glue Wrap the threads of the sensor using Teflon plumbers tape and...

Страница 8: ...roll to switch between them then press the Enter key Two different methods of tank programming are available if using the pressure sensor 2 Point Calibration sets tank low and high points which can on...

Страница 9: ...ing Level Please Wait The display will now show Fill the tank to the TANK HIGH LEVEL Wait for approx 60 seconds for the fluid to settle and press the Enter key The display will show Setting Level Plea...

Страница 10: ...show Fill the tank to the 1 4 LEVEL Wait for approx 60 seconds for the fluid to settle and press the Enter key The display will show Setting 1 4 Please Wait The display will now show Fill the tank to...

Страница 11: ...ation Tips Tricks on our web site www smartswitch co nz Table 1 SmartSwitch strongly recommends that Table 1 be used to record voltages for each tank level at time of tank calibration These voltages w...