TD-1000
Tank Monitor
Installation Manual
Страница 1: ...TD 1000 Tank Monitor Installation Manual...
Страница 2: ...300Ma 12vdc Pump output 4 Amps 12vdc Size 65mm x 65mm x 80mm Deep Data Retention 50 years without power Outputs Pump Output 4 Amps 12vdc The TD 1000 has one output which can be used to control an int...
Страница 3: ...3 TD 1000 Wiring Red Battery Black Sensor Black Buzzer Blue Buzzer White Output Green Sensor In Black Battery Purple Sensor Connector Mounting 50mm Size 75mm x 75mm Drill a hole using a 50mm hole saw...
Страница 4: ...te Relay Toilet Disable Connection Toilet Pump Toilet Pump Blue wire Relay Toilet Disable Connected to SmartSwitch Toilet controller connect blue output wire to SmartSwitch STS 220 toilet controller a...
Страница 5: ...ush the Enter button to select the tank Name or scroll to another name PLEASE SEE PAGE 8 FOR SENSOR CALIBRATION Step 3 Setting the Alarm point The display will now show The alarm point is the point wh...
Страница 6: ...ed the pump output will turn on and automatically turn Off when the Pump Off point is reached If the tank name is either Black or Grey the pump will stop when the tank is equal to or less than the pro...
Страница 7: ...e adaptor is attached make sure that the hole in the adaptor is clear of any excess glue Allow drying as per the instructions for the glue Wrap the threads of the sensor using Teflon plumbers tape and...
Страница 8: ...roll to switch between them then press the Enter key Two different methods of tank programming are available if using the pressure sensor 2 Point Calibration sets tank low and high points which can on...
Страница 9: ...ing Level Please Wait The display will now show Fill the tank to the TANK HIGH LEVEL Wait for approx 60 seconds for the fluid to settle and press the Enter key The display will show Setting Level Plea...
Страница 10: ...show Fill the tank to the 1 4 LEVEL Wait for approx 60 seconds for the fluid to settle and press the Enter key The display will show Setting 1 4 Please Wait The display will now show Fill the tank to...
Страница 11: ...ation Tips Tricks on our web site www smartswitch co nz Table 1 SmartSwitch strongly recommends that Table 1 be used to record voltages for each tank level at time of tank calibration These voltages w...
Страница 12: ...design and Intellectual Property is owned by Penguin Electronics Ltd Po Box 272 Waikanae New Zealand Ph 0064 4 293 4201 Fax 0064 4 293 4201 Mobile 0064 274 919 805 Email info smartswitch co nz Web ww...