10
Instructions for Programming a Group Controller for Non-Simplex jobs
The group controller software will be located in the Controller Software folder.
Locate the folder with the group software in it. The folder will clearly be labeled “Group
Software.” After locating the folder, proceed below.
1.
A controller cannot be programmed if unpowered, ensure that you have 24V supplied to
the controller.
2.
Activate
Dip Switch #1
on the group controller. (The group controller will not fault like
the machine room controller)
3.
Plug in the programming pod into the J21 port first. Select the J21 checkbox on the
Smartrise programming application show below.
4.
Next, click the “
Begin Programming
” button on the bottom of the programming interface
to begin programming the board.
5.
Notice the progress report bar, when programming is finished, the LCD display will show
"
Progress: Done
”. NOTE: Verify that the POWER and RUN LED’s on the programming pod
itself are off before disconnecting it from a controller.
6.
Next move the programming pod from port J21 to J22, click on the J22 check box and the
“Begin Programming” button.
7.
When programming is finished:
CYCLE POWER
–
**
DO NOT PRESS THE RESET BUTTON
**
8.
Next, go to the
MAIN MENU | SET UP | DEFAULT ALL |
select “Yes” and press the center
button. The controller will begin to default all the factory parameters (This could take
several minutes).
9.
Once this is finished, cycle power again.
10.
When the controller is fully powered and finished loading, turn off
Dip Switch 1
.
11.
Verify that the controller is programmed correctly. This is done by going to the
MAIN
MENU | ABOUT
.
If all the information is correct, the controller software has been
successfully installed.