November 22, 2017
Please note that in the standard configuration the sensor has no 120Ohms resistor on board
(CAN bus termination between CAN_Lo and CAN_Hi and RS485 IN / OUT). The resistors are
nevertheless required at either end of a CAN / RS485 bus and is in most cases integrated in
the cable delivered along with the sensor (if cable is manufactured by Smartmicro).
For the RS485 data interface there is a 120Ohms resistor on board of the sensor.
A number of cable sets for initial operation and test purposes are offered by Smartmicro, to
deliver a fast set-up of a sensor system. Among those preconfigured ready-to-run cables as
well as cable stumps (pig tail cables or various lengths) which carry the connector on one side
and open wires on the other.