OM_Axessor_CIT_V024_20170518_EN.pdf Operating
Manual
Page 46
Subject to change without prior notice
Axessor CIT
5.8.2.4
Courier
Code
1 Courier Code (Courier Code ID 90) can be provided to personnel filling/
emptying secured containers (CIT - Cash-In-Transit Services) without any
programmed Time Delays being of relevance.
Factory setting:
no code assigned
Functions:
Opening the lock (even alone in Dual Mode) by bypassing
Time Delay
Alteration of Courier Code
AS284-USBW or AS284-NETW Programming Software
The Courier Code can be defi ned as: „Courier does not Open but Skips Delay“.
Thereupon, entering the Courier Code for lock opening skips the Time Delay
for the next opening. The Confi rmation window count-down indicates for how
long this condition is given (opening procedure must start during count-down).
5.8.3 Shelve
Function
The shelve function is only available if the programming mode is accessed
with Master Code. With the shelve function you reset all codes, param-
eters and data (e.g Locking Periods, Time Delays etc.) to factory default
settings.
Audit Trail, opening counter and Time/Date settings remain unchanged.
Note!
After resetting the lock is in bank mode again, even if the lock has been acti-
vated in a one time code mode.
5.8.4
Duress
Code
If the lock is connected to an external alarm system, a silent duress alarm
(unnoticeable for the aggressor) can be initiated by the operator. The way
to trigger a duress alarm depends on the current operation mode.
5.8.4.1 Duress Code in bank mode
To trigger a duress alarm in bank mode, the
value 1 has to be added or
deducted to the last digit of the code as standard
. Duress alarms can be
initiated with all code types at any time.
Important
: with the Programming Software AS284-USBW or AS284-
NETW the format of the Duress Code can be modified and may differ
from the rule mentioned above.
Example:
Code
Duress Code
0012345
6
---->
0012345
7
or 0012345
5
0000000
0
---->
0000000
1
or 0000000
9
0099999
9
---->
0099999
0
or 0099999
8
Entering the Duress Code for lock opening starts the set Duress Time