Страница 1: ...HGM7220N HGM7220S SERIES GENSET CONTROLLER USER MANUAL SMARTGEN ZHENGZHOU TECHNOLOGY CO LTD...

Страница 2: ...tart genset in manual mode Manual Set the module to manual mode Auto Set the module to auto mode C O Control breaker close and open in manual mode Set Confirm Enter menu list page Move cursor in param...

Страница 3: ...alarm fast flashing 5 times per second Trip and stop alarm fast flashing 5 times per second NOTES a Status Indicators illuminate always after crank disconnection and before ETS extinguished during ot...

Страница 4: ...start idle delay is initiated if configured g During start idle delay period under speed under frequency under voltage alarms are inhibited When this delay is over warming up delay starts if configure...

Страница 5: ...ter after stop delay and failed to stop alarm will be eliminated automatically g When after stop delay is over genset shall enter standby status 4 4 MANUAL START STOP OPERATION a HGM7220N 7220S Press...

Страница 6: ...generator close occurs In the process of generator close transfer failure is detected When the detection time is due if close fails then generator close is waited for If transfer failure warning is e...

Страница 7: ...of waiting for synchronization or if synchronization fails press generator C O button to cancel synchronization and generator breaker is open Then press mains C O button to force mains on load Mains D...

Страница 8: ...nd action is selected Trip it will send trip signals 3 Over Power When controller detects that the genset power value power is positive exceeds the pre set value and action is selected Trip it will se...

Страница 9: ...20N HGM7220S GENSET CONTROLLER USER MANUAL HGM7220N HGM7220S Genset Controller 2019 02 28 Version 1 0 Page 21 of 60 7 WIRINGS CONNECTION HGM7220N 7220S controller back panel is as below Figure 2 Back...

Страница 10: ...250VAC 2 5 mm2 13 14 Charger D 1 0mm2 Connected with charger starter s D WL terminal Please hang it up if there is not this terminal 15 Aux Output 5 8A 1 5 mm2 B is supplied by Terminal 2 rated 8A Fo...

Страница 11: ...0mm2 Connected to W phase output of genset 2A fuse recommended 39 Gen N2 line Input 1 0mm2 Connected to N line output of genset 40 Mains R phase Voltage Monitoring Input 1 0mm2 Connected to R phase of...

Страница 12: ...e percentage return value and delay value also can be set 9 Under Voltage 0 200 80 10 Over Frequency 0 200 Disabled The setting value is mains rated frequency percentage return value and delay value a...

Страница 13: ...Server www monitoryun com 3 Server Port 0 65535 91 4 Module Password 123456 16 characters 8 2 DEFINITION CONTENT OF PROGRAMMABLE OUTPUT PORTS 1 6 Table 11 Programmable Output Ports 1 6 No Type Descri...

Страница 14: ...button and genset will start After the cranking times set before controller will send signal of Start Failure then press stop to reset controller Recover the action to prevent engine from cranking suc...

Страница 15: ...GM7220S GENSET CONTROLLER USER MANUAL HGM7220N HGM7220S Genset Controller 2019 02 28 Version 1 0 Page 46 of 60 13 TYPICAL APPLICATION Figure 4 HGM7220S Typical Application Figure 5 HGM7220N Typical Ap...

Страница 16: ...h capacity in start and fuel output is recommend 14 INSTALLATION 14 1 SGE02 EXPANSION MODULE 14 1 1 4G ANTENNA PORT Connect 4G antenna and 4G port of SGE02 Antenna port 50 SMA USB 14 1 2 GPS ANTENNA P...

Страница 17: ...ys on the controller and this means SIM is not inserted or SIM contact is not good Please refer to the following installation steps Figure 9 SIM Installation Steps 14 2 FIXING CLIPS Controller is pane...

Страница 18: ...ithin 1 24 VAC effective value during the full speed 12VAC is recommended in rated speed When the speed sensor is installed let the sensor spun to contacting flywheel first then make it back 1 3 lap a...