9
SMARTEK Vision | User Manual – LED Strobe Controller Family | Doc. v2.1.1
2.3.4.
Trigger Output
Every controller provides a generic trigger output (
OUT
) for synchronization of other devices.
The connector assignment is described in Table 8.
Pin#
HPSC1
HPSC4
Connector
Type
Phoenix Contact
MSTB 2,5/ 2-ST-5,08
Phoenix Contact
MSTB 2,5/ 8-ST-5,08
OUT+
Trigger Output n +
OUT-
Trigger Output n -
Table 8: Tigger Output (OUT) connector description HPSC-Series
The limits of each line are shown in Table 9, the internal circuitry of the HPSC1 in Figure 3,
for HPSC4 in Figure 4.
Interface
OUT
Type
Open-collector
Max. rating
30V / 50mA
Table 9: HPSC-Series – Trigger Output (OUT) maximum ratings
Figure 3: HPSC1 – Trigger Output (OUT) – Schematics
BC847C
GND
SMCJ24A
TRO
H
PSC1
OUT +
OUT -
BC847C
GND
SMCJ24A
TRO
HPSC1
OUT +
OUT -
OUT
+
-
OUT1 OUT2 OUT3 OUT4
+
- + - + - + -