CHAPTER 2
MOUNTING THE INTERACTIVE FLAT PANEL
12
l
Use a standard VESA mounting plate (not included) to mount the interactive flat panel on a
wall.
l
Use M8 screws to fasten the wall bracket.
Screw length
20 mm +
x
mm < M8 < 45 mm +
x
mm
where
x
is the combined thickness of the wall bracket and washer
Fasten force
97.36–177.01 in-lb. (11–20 N·m)
CAUTION
Do not over-tighten the screws.
NOTE
SMART recommends M8 × 30 mm mounting screws for standard installations where the
total wall mount bracket and washer thickness is less than 7 mm.
l
Because the receptacles might not be easily accessible after the installers mount the
interactive flat panel, consider connecting cables for power, computers and other devices
while the interactive flat panel is still in its packaging (see
Chapter 3: Connecting power and
l
Before turning on the interactive flat panel for the first time, clean the camera windows and
reflective tape following the instructions in
Cleaning the camera windows and reflective tape
Mounting the interactive flat panel vertically
The interactive flat panel is designed for vertical mounting (90° relative to the
floor plus or minus 5° for tolerance). SMART doesn’t support mounting the
interactive flat panel at other angles.