Stop-Down Troubleshooting 

 

For any fault on Smartlift, first look into the options below: 

 

 

Has anything visible been broken, or is anything unusual, about the machine? Is there any 

murmuring or noise? 

 

Have the batteries been charged, and the main switch switched on? (the On/Off button on the 

drive handle shall have been switched on (lighting) to read battery voltage on battery indicator) 

 

Has the emergency stop button switched the machine off? (placed on grey control box)  

 

Has the safety switch been switched off on account of overloading (placed under pressure 

switches)? 

 

Is the hose set intact, and has it been connected correctly? 

 

Troubleshooting and remedying of faults will be divided into

    

3 overall categories: 

 

1.

 

Vacuum

 

(machine capacity for sucking work)

  

2.

 

Movements controlled via control panel 

up and down function of lift arm, tilting of 

yoke, side displacement of machine. 

3.

 

Drive controlled by regulating lever 

– 

Forward and back function of machine.

  

 

 

©  2006 Copyright.  www.smartlift.dk

 

 

 

Содержание SL 380 MIDI

Страница 1: ...I 03 2016 1 User Manual Model type SL 380 MIDI 0 95 hp N A Christensensvej 39 DK 7900 Nyk bing Mors Tlf 45 97 72 29 11 Fax 45 97 72 39 11 E mail smart smartlift dk www smartlift dk 2006 Copyright www...

Страница 2: ...w General Description 8 Operation for Vacuum function 10 Control for arm and yoke 10 Important Operation vacuum electric functions 11 Electric Functions 11 Charger Battery Case 12 View of Vacuum syste...

Страница 3: ...guarded This is why safety rules have been prepared by way of warnings in this instruction Read these safety rules on the following pages before putting your Smart LIFT into operation and imagine how...

Страница 4: ...reached by upper and lower limbs DS EN ISO 13849 1 Safety of machinery Safety related parts of control systems Part 1 General principles for design DS EN 13155 A2 Cranes Safety Non fixed load lifting...

Страница 5: ...p MRX 80 P M10 25 6 21 Actuator Tilting function LA 36 1 22 Actuator Side Change 1 23 Actuator Telescopic Arm 1 24 Actuator Lift Arm LA 36 2 Power Supply 25 Battery 62 AK Battery Case 2 26 Charger CTE...

Страница 6: ...now Lifting by crane or similar Always lift Smart Lift in lift eye intended for this purpose pos 41 NEVER lift under Smart LIFT by forks truck and similar For transport on the transport frame Smart Li...

Страница 7: ...oose objects on the machine since this would entail breakdown and danger risks WARNING Vacuum Working at the machine will entail danger if the various safety devices pressure gauge pos 6 and acoustic...

Страница 8: ...work is strictly prohibited PROHIBITED May NOT be used for person lifting Overview General Description pages 8 9 11 14 Telescopic Arm 21 Actuator tilting function 2 Suction Cups diam 11 8 in Vacuum Ch...

Страница 9: ...activation and deactivation of vacuum suction 2 circuit system 32 Control Panel in holder 5 Slide Valve w lock Vacuum 2006 Copyright www smartlift dk 2006 Copyright www smartlift dk 31 Overload safety...

Страница 10: ...h the functioning of the machine Smart LIFT is operated manually This machine generally has four functions which may be operated individually UP DOWN function This function will make the arm move eith...

Страница 11: ...ctivating the safety switch will stop the car and the car will move forward Important Operation vacuum electric function 51 Safety function f back machine moving forward automatically 32 Control Panel...

Страница 12: ...a maximum charge time of 18 hours Connection to the mains or reduction of the output voltage to 12V resp 24V due to a DC load will trigger a new charge cycle Also please refer to the attached user gu...

Страница 13: ...acuum Load Diagram 2006 Copyright www smartlift dk 17 Line filter f vacuum suction 1 Vacuum pump 2006 Copyright www smartlift dk For max stability at transport of sucked work the suction cups are to b...

Страница 14: ...f the battery case Must be switched off after use 2006 Copyright www smartlift dk 2006 Copyright www smartlift dk 34 Controller lifting arm 39 Fuse 30 Ampere 36 Controller side shift 35 Controller tel...

Страница 15: ...80 MIDI 03 2016 15 Control Panel for arm and yoke pos 32 Lift Arm Down Tilt back Telescopic arm out Side shift left Lift arm up Tilt forward Telescopic Arm in Side shift right 2006 Copyright www smart...

Страница 16: ...US SL 380 MIDI 03 2016 16 LOAD DIAGRAM 2006 Copyright www smartlift dk...

Страница 17: ...icator Has the emergency stop button switched the machine off placed on grey control box Has the safety switch been switched off on account of overloading placed under pressure switches Is the hose se...

Страница 18: ...stantly appr 0 55 or less and the pump is running In that case there would be a fault on the vacuum pump or a leak on the hose connection between check valve and vacuum pump If the pressure gauge indi...

Страница 19: ...rvals possibly with dropping pressure on one or both pressure gauges when the slide valve is opened after correct suction of work Close slide valve Disconnect one vacuum circuit at hose coupling and t...

Страница 20: ...cator Is 30 ampere fuse in control box OK Has the safety switch been activated If activated try to deactivate by pulling in the telescopic arm or act as follows The safety switch has correctly switche...

Страница 21: ...ew from one of the actuators Lines may be loose or torn and bolts may be loose Finally the actual actuator telescopic arm may be bent The machine has totally five actuators 1 for tilting of yoke 2 for...

Страница 22: ...ctuator for side change 80 A Fuse f drive motor If the lift actuators or one of these stop due to unbalanced load one of the safety switches under the actuators will have switched off the power supply...

Страница 23: ...r all actuators Faults on movement of actuators can be diagnosed by measuring systematically as described in the following two pages Controller for tilting actuator Controller for telecoping actuator...

Страница 24: ...the remote control Voltage between clamp 1 and 9 and 1 and 10 must be approx 24 Volt Possible faults on pulses from lifting actuator can be checked by activating the control panel in steps At the same...

Страница 25: ...ween Clamps 1 and 6 as between 1 and 7 Fault on remote control when moving single actuators Voltage must be 24 Volt between clamps 1 and 9 as between 1 and 10 Activate the control panel for movement o...

Страница 26: ...the screen at the front of the machine OK Check regulating lever and cables for visible faults and damage There may be no faults on lever or control unit Control light on switch may show error code a...

Страница 27: ...mplete manual refer to https www victronenergy com upload documents Datasheet Blue Power Battery Charger IP65 90 135VAC EN pdf LED indication Description Yellow LED on battery being charged Yellow LED...

Страница 28: ...US SL 380 MIDI 03 2016 28 WIRING DIAGRAMS 2006 Copyright www smartlift dk...

Страница 29: ...US SL 380 MIDI 03 2016 29 2006 Copyright www smartlift dk...

Страница 30: ...US SL 380 MIDI 03 2016 30 2006 Copyright www smartlift dk...

Отзывы: