Maintenance Procedures
4.3
Figure 4.1 - Transducer Rotation
Loosen the two screws
(3)
that anchor the indicator and the main circuit board. Gently pull out the
indicator, and then the main board
(5)
.
Reassembly Procedure
WARNING
Do not assemble the main board with power on.
Transducer
Mount the transducer to the housing turning clockwise until it stops. Then turn it counterclockwise
until it faces the square of electronic housing to the square of transducer. Tighten the hex screw
(6)
to lock the housing to the transducer.
Electronic Circuit
Plug transducer connector and power supply connector to main board
(5)
. Attach the display to the
main board. Observe the four possible mounting positions. The
mark indicates up position.
Figure 4.2 – Display - Four Possible Positions
Anchor the main board
(5)
in the housing
(8)
with their screws
(3)
. After tightening the protective
cover
(1)
, mounting procedure is complete. The transmitter is ready to be energized and tested.