SMAR RHP303 Скачать руководство пользователя страница 3

RHP303 –Profibus Hub Repeater 

 

 

AVOIDING ELECTROSTATIC DISCHARGES 

 
 
 
 
 

 
 
 
 

NOTE 

To ensure that our products are safe and without risk to health, read the manual carefully prior to 
installation.

 

Installation, operation, maintenance and repair should only be performed by trained 

personnel and according to the User Manual. 

 
 
 
Updated information about the Smar products can be obtained directly on http://www.smar.com 
 
 
 

ATTENTION 

Electrostatic discharges may damage semiconductor electronic components in printed circuit 
boards. They usually occur when touching components or connector pins from modules and racks, 
without wearing the appropriate equipment to prevent discharges. It is recommended to take the 
following precautions: 

 

Before handling modules and racks, remove the electrostatic charge from your body by 
wearing a proper wristband or touching grounded devices; 

 

Avoid touching electronic components or connector pins from racks and modules. 

Содержание RHP303

Страница 1: ...RHP303 PROFIBUS HUB REPEATER USER S MANUAL R H P 3 0 3 M E...

Страница 2: ...web www smar com contactus asp www smar com Specifications and information are subject to change without notice Up to date address information is available on our website smar...

Страница 3: ...ined directly on http www smar com ATTENTION Electrostatic discharges may damage semiconductor electronic components in printed circuit boards They usually occur when touching components or connector...

Страница 4: ...a spur do not spread to other segments The RHP303 smart circuits and its insulation do not electrically modify the communication signal These circuits also identify automatically the transmission spe...

Страница 5: ...equipment Large star tree structured networks Examples of Application The figure below shows a general RHP303 application Each insulated channel prevents short circuit propagation from one channel to...

Страница 6: ...OFIBUS DP cable lengths See on the table below the relation between the several communication rates and the allowed lengths Make sure the cables on the main channel A and the derived channels B to F c...

Страница 7: ...f off off off off off 187 5 Kbps off off off off ON off off off off off 500 Kbps off off off off off ON off off off off 1 5 Mbps off off off off off off ON off off off 3 0 Mbps off off off off off off...

Страница 8: ...on the channel is receiving a valid signal Reception RX LED Invalid or non existing signal Off Receiving a valid signal On Figure 7 RX LEDs to indicate signal reception Installation The RHP303 can be...

Страница 9: ...te Power supply The power supply connector a 3 pin terminal block is located on the RHP303 lower left corner The power supply must comply with the Technical Specifications topic Figure 9 Detail of the...

Страница 10: ...egment end NOTE Non used channels must have their terminators activated Figure 11 Detail of channel terminators position Baud Rate Configuration The RHP303 recognizes the transmission speed by default...

Страница 11: ...OWER SUPPLY Power connector 3 pin terminal block Voltage 12 to 30 Vdc 24 Vdc nominal Maximum current 270 mA 24 Vdc Protection against reverse polarity Yes Cabling 2 5 mm 2 FUNCTION SPECIFICATIONS Supp...

Страница 12: ...nts SPARE COMPONENTS LIST COMPONENTS DESCRIPTION C DE 5 x 20 mm Fuse 500 mA package with 10 pieces 400 1241 Dimensional Drawings The sizes are in millimeters and in brackets for inches 65 2 55 138 5 4...

Страница 13: ...RHP303 User s Manual 13...

Страница 14: ...RHP303 Profibus Hub Repeater 14...

Страница 15: ..._____________________________ FAILURE DESCRIPTON Please describe the failure Can the error be reproduced Is it repetitive ______________________________________________________________________________...

Страница 16: ...RHP303 Profibus Hub Repeater A 2...

Отзывы: