Maintenance Procedure
4.9
209-0241 SPARE PART NUMBER FOR FLANGED PRESSURE SENSOR
COD. Type
Range Limits
Min. Max.
Min. Span
Unit
Range Limits
Min. Max.
Min. Span
Unit
L2
L3
L4
L5
Level
Level
Level
Level
-50
-250
-2500
-25000
50
250
2500
25000
1,25
2,08
20,83
208,30
kPa
kPa
kPa
kPa
-200
-36
-360
-3625
200
36
360
3625
5
0,3
3
30,2
inH
2
O
psi
psi
psi
Note: The range can be extended up to 0.75
LRL and 1.2 URL with small degradation of
accuracy. The upper range value must be
limited to the flange rating.
COD. Diaphragm Material (Sensor) and Fill Fluid (Sensor)
1
316L SST - Silicone Oil
COD. Process Connection
U
V
W
O
P
Q
9
A
B
1
2
1” 150# (ANSI B16.5)
1” 300# (ANSI B16.5)
1” 600# (ANSI B16.5)
1½” 150# (ANSI B16.5)
1½” 300# (ANSI B16.5)
1½” 600# (ANSI B16.5)
2” 150# (ANSI B16.5)
2” 300# (ANSI B16.5)
2” 600# (ANSI B16.5)
3" 150 # (ANSI B16.5)
3” 300# (ANSI B16.5)
C
3
4
D
5
R
E
6
7
8
Z
3” 600# (ANSI B16.5)
4” 150# (ANSI B16.5)
4” 300# (ANSI B16.5)
4” 600# (ANSI B16.5)
DN25 PN 10/40
DN40 PN 10/10
DN50 PN10/40
DN80 PN25/40
DN100 PN10/16
DN100 PN25/40
User´s specifications
COD. Type and Material Flange
4
5
304 SST (slip-on flange)
316 SST (slip-on flange)
6
Z
Carbon Steel (slip-on flange)
User´s specifications
COD
.
Extension Lenght
0
1
2
0 mm (0”)
50 mm (2”)
100 mm (4”)
3
4
Z
150 mm (6”)
200 mm (8”)
User´s specifications
COD. Diaphragm Material/Extension (Process Connection)
1
2
3
4
316 L SST / 316 SST
Hastelloy C276 / 316 SST
Monel 400 / 316 SST
Tantalum / 316 SST
(3)
5
6
L
Z
Titanium / 316 SST
(3)
316L SST with Teflon Lining
316L SST with Halar Lining
User´s specifications
COD. Fill Fluid (Process Connection)
S
F
D
K
Silicone DC-200/20 Oil
Inert Fluorolube MO-10 Oil
(4)
Silicone DC-704 Oil
Krytox Oil
H
N
T
Z
Halocarbon 4.2 Oil
Propileno Glicol (Neobee) Oil
Syltherm 800 Oil
User´s specifications
COD. Lower Housing Material
0
1
2
3
Without Lower Housing
316L SST
Hastelloy C276
Super Duplex (UNS 32750)
4
5
Z
Duplex (UNS 31803)
304L SST
User´s specifications
COD. Gasket Material
0
C
G
Without Gasket
Copper
Grafoil (Flaxible Lead)
T
Z
Teflon (PTFE)
User´s specifications
209-0241
L2
1
1
6
0
1
S
1
0
TYPICAL MODEL NUMBER
NOTES
(1)
Silicone Oils not recommendations for Oxygen (O
2
) or Chlorine service.
(2)
Not applicable for vacuum service.
(3)
Attention, check corrosion rate for the process, tantalum plate 0.1 mm, AISI 316L extension 3 to 6mm.
(4)
Fluorolube fill fluid is not available for Monel diaphragm.
(5)
Inert Fluid: Safe for oxygen service.
Содержание LD290
Страница 1: ......
Страница 2: ......
Страница 6: ...LD290 Operation and Maintenance Instruction Manual VI...
Страница 9: ...Installation 1 3 Figure 1 1 b Dimensional Drawing and Mounting Position for LD290 Sanitary...
Страница 11: ...Installation 1 5 Figure 1 1 d Dimensional Drawing and Mounting Position for LD290 Level...
Страница 18: ...LD290 Operation and Maintenance Instruction Manual 1 12...
Страница 32: ...LD290 Operation and Maintenance Instruction Manual 3 10...
Страница 37: ...Maintenance Procedure 4 5 16 18 6 8 9 10 11 12 13 14 15 17 5 1 2 3 4 7 19 Figure 4 1 Exploded View...
Страница 42: ...LD290 Operation and Maintenance Instruction Manual 4 10...
Страница 61: ...Appendix A A 7 CEPEL Centro de Pesquisa de Energia El trica...
Страница 62: ...LD290 Certifications Information A 8...
Страница 63: ...Appendix A A 9 FM Approvals...
Страница 64: ...LD290 Certifications Information A 10...
Страница 66: ...LD290 Appendix B B 2...